AIRAWAT-PSAI

AIRAWAT-PSAI is an operational AI data center operated by Center for Development of Advanced Computing (C-DAC) in Pune, India. Its power is about 0.5 MW. Epoch AI estimates about 207 H100-equivalent AI chips (NVIDIA A100).

Key facts

StatusOperational
OperatorCenter for Development of Advanced Computing (C-DAC)
Facility power0.5 MW
Reported (Epoch AI or owner data)
AI compute207 H100-equivalents
AI chipsNVIDIA A100
Reported (Epoch AI or owner data)
Chip count656
Largest reported cluster at this site (Epoch AI).
GPU capacity if all AIabout 230 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
AddressInnovation Park, 34/B/1, Panchawati Rd, Mansarovar, Panchawati, Pashan, Pune, Maharashtra 411008, India
Coordinates18.53390, 73.81164

Power and grid

Nearest high-voltage substationUnnamed substation, 132 kV, 4.2 km away (MSETCL)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationSinhagad Road Substation (Parvati), 220 kV, 5.4 km away
HV substations within 10 km6
Power plants within 50 km393 MW in 4 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity666 g CO₂ per kWh (India, 2025)
Average of all power made in the area. Ember.
Grid power mixcoal 70%, solar 9.8%, hydro 8.5%, wind 5%, nuclear 2.6%. Clean power: 27.1%

Climate and water

Average temperature23.9 °C
NASA POWER, average of 2001 to 2025.
Highest temperature43.2 °C (2001 to 2025)
Cooling degree days2,307 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy5.4 kWh per m² per day
Wind at 50 m5.4 m/s average
Water stress todayExtremely High (>80%) (Maharashtra)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Extremely High (>80%)
Business-as-usual scenario.

GPU clusters at this site

ClusterChipsCountPowerSince
PARAM Siddhi-AI Phase 1NVIDIA A1003360.3 MW2020-11-01
AIRAWAT-PSAI Phase 2NVIDIA A1006560.5 MW2023-05-23

Source: Epoch AI GPU Clusters.

Satellite view

Questions

How much power does AIRAWAT-PSAI use?

Public data puts the facility power at about 0.5 MW. Reported (Epoch AI or owner data).

What chips does AIRAWAT-PSAI use?

Reported chips: NVIDIA A100.

How close is AIRAWAT-PSAI to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (132 kV), about 4.2 km away.

How clean is the power for AIRAWAT-PSAI?

The grid in India emits about 666 g CO₂ per kWh (2025). Largest sources: coal 70%, solar 9.8%, hydro 8.5%.

Who operates AIRAWAT-PSAI?

Center for Development of Advanced Computing (C-DAC).