Angeles Data Center
Angeles Data Center is an operational data center operated by Converge ICT Solutions in Angeles City, Philippines. Our footprint estimate of its power is about 2.4 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Converge ICT Solutions |
| Facility power | 2.4 MW (range 0.9 MW to 5.9 MW) Estimate from building footprint, low confidence. Footprint estimate: about 19,678 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 1,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 15.16797, 120.60560 |
Power and grid
| Nearest high-voltage substation | Clark Substation, 230 kV, 8.2 km away (Clark Electric Distribution Company) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 1 |
| Power plants within 50 km | 402 MW in 9 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 569 g CO₂ per kWh (Philippines, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 55.8%, gas 16.4%, hydro 9.8%, other renewables 7.8%, solar 7.1%. Clean power: 27% |
Climate and water
| Average temperature | 26.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.3 °C (2001 to 2025) |
| Cooling degree days | 3,185 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.08 kWh per m² per day |
| Wind at 50 m | 4.8 m/s average |
| Water stress today | Medium - High (20-40%) (Philippines) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Angeles Data Center use?
We estimate the facility power at about 2.4 MW. Estimate from building footprint, low confidence.
How close is Angeles Data Center to the power grid?
The nearest high-voltage substation in OpenStreetMap is Clark Substation (230 kV), about 8.2 km away.
How clean is the power for Angeles Data Center?
The grid in Philippines emits about 569 g CO₂ per kWh (2025). Largest sources: coal 55.8%, gas 16.4%, hydro 9.8%.
Who operates Angeles Data Center?
Converge ICT Solutions.
Data centers near Angeles City
- VITRO Clark 9.2 km
- STTGDC FVW1 71.6 km
- STT Fairview Data Centre 72.4 km · 5.1 MW
- STT Quezon City (Formerly QC2) 73.0 km
- PLDT Diliman 75.2 km
- Alibaba Cloud in Philippines 75.3 km
- Dataone Asia Philippines 80.5 km
- SHIFT DATA - Yuchengco Tower 80.6 km
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.