Data Center Directory

atNorth ICE01

atNorth ICE01 is an operational data center operated by atNorth in Hafnafjörður, Iceland. Our footprint estimate of its power is about 3.4 MW.

Key facts

StatusOperational
OperatoratNorth
Facility power3.4 MW (range 1.7 MW to 5.5 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 2,841 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 1,500 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
AddressSteinhella 10
Opened2006
Coordinates64.04947, -21.99353
Websiteatnorth.com/nordic-data-centers/iceland-data-centers/reykjavik-metro-site

Power and grid

Nearest high-voltage substationAðveitustöð, 220 kV, 1.2 km away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km5
Power plants within 50 km592 MW in 7 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity28 g CO₂ per kWh (Iceland, 2025)
Average of all power made in the area. Ember.
Grid power mixhydro 71.2%, other renewables 28.7%. Clean power: 100%
Industrial power priceEUR 0.090 per kWh (Iceland, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature4.6 °C
NASA POWER, average of 2001 to 2025.
Highest temperature22.8 °C (2001 to 2025)
Cooling degree days0 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.26 kWh per m² per day
Wind at 50 m7.1 m/s average
Water stress todayLow (<10%) (Iceland)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Low (<10%)
Business-as-usual scenario.

Satellite view

Questions

How much power does atNorth ICE01 use?

We estimate the facility power at about 3.4 MW. Estimate from building footprint, low confidence.

How close is atNorth ICE01 to the power grid?

The nearest high-voltage substation in OpenStreetMap is Aðveitustöð (220 kV), about 1.2 km away.

How clean is the power for atNorth ICE01?

The grid in Iceland emits about 28 g CO₂ per kWh (2025). Largest sources: hydro 71.2%, other renewables 28.7%.

Who operates atNorth ICE01?

atNorth.

Data centers near Hafnafjörður

More atNorth data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.