Colo4Dallas
Colo4Dallas is an operational data center operated by Colo4Dallas in Dallas, United States. Our footprint estimate of its power is about 8.3 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Colo4Dallas |
| Facility power | 8.3 MW (range 4.2 MW to 13 MW) Estimate from building footprint, low confidence. Footprint estimate: about 6,922 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,500 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 14 networks, 1 internet exchanges PeeringDB. |
| Also known as | TierPoint Dallas · ColoCrossing DFW1 · TierPoint Dallas Data Center |
| Address | 3000 Irving Blvd. |
| Coordinates | 32.80789, -96.85730 |
| Website | colo4dallas.com |
Power and grid
| Utility | Hilco Electric Cooperative, INC. (cooperative) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | ERCO |
| Nearest gas pipeline | Gulf South Pipeline Co, interstate pipeline, 8.4 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 379 g CO₂ per kWh (Texas, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8% |
| Industrial power price | USD 0.072 per kWh (Texas, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 18.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 45.3 °C (2001 to 2025) |
| Cooling degree days | 1,559 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.64 kWh per m² per day |
| Wind at 50 m | 6.5 m/s average |
| Water stress today | High (40-80%) (Texas) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Colo4Dallas use?
We estimate the facility power at about 8.3 MW. Estimate from building footprint, low confidence.
How clean is the power for Colo4Dallas?
The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.
Who operates Colo4Dallas?
Colo4Dallas.
Data centers near Dallas
- Level(3) Dallas 1.0 km · 7 MW
- CoreSpace Dallas 1.8 km · 6.8 MW
- DataBank Dallas (DFW4) 2.1 km · 11 MW
- 3HCloud - DFW-1 2.7 km
- Lumen Dallas 6 3.4 km · 2.2 MW
- DataBank Dallas (DFW6) 3.5 km
- Equinix DA1 - Dallas 3.6 km · 196 MW
- Flexential Dallas - Downtown Dallas 3.6 km