Continental DGX Supercomputer
Continental DGX Supercomputer is an operational AI data center operated by Continental in Frankfurt am Main, Germany. Its power is about 0.3 MW. Epoch AI estimates about 28 H100-equivalent AI chips (NVIDIA V100).
Key facts
| Status | Operational |
|---|---|
| Operator | Continental |
| Facility power | 0.3 MW Reported (Epoch AI or owner data) |
| AI compute | 28 H100-equivalents |
| AI chips | NVIDIA V100 Reported (Epoch AI or owner data) |
| Chip count | 448 Largest reported cluster at this site (Epoch AI). |
| GPU capacity if all AI | about 130 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Frankfurt, Germany |
| Coordinates | 50.11060, 8.68301 |
Power and grid
| Nearest high-voltage substation | Umspannwerk Hochstraße, 110 kV, 800 m away (Mainova) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Frankfurt Südwest, 380 kV, 5 km away |
| HV substations within 10 km | 32 |
| Power plants within 50 km | 3.3 GW in 43 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.8 °C (2001 to 2025) |
| Cooling degree days | 233 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.98 kWh per m² per day |
| Wind at 50 m | 5.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
GPU clusters at this site
| Cluster | Chips | Count | Power | Since |
|---|---|---|---|---|
| Continental DGX Supercomputer | NVIDIA V100 | 448 | 0.3 MW | 2020-07-28 |
Source: Epoch AI GPU Clusters.
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Continental DGX Supercomputer use?
Public data puts the facility power at about 0.3 MW. Reported (Epoch AI or owner data).
What chips does Continental DGX Supercomputer use?
Reported chips: NVIDIA V100.
How close is Continental DGX Supercomputer to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Hochstraße (110 kV), about 800 m away.
How clean is the power for Continental DGX Supercomputer?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates Continental DGX Supercomputer?
Continental.
Data centers near Frankfurt am Main
- INTERNIC Frankfurt 1.3 km
- Dawico FFM 1.5 km
- euNetworks Colocation Frankfurt 2.6 km
- firstcolo - FRA1 3.1 km
- Equinix FR7 - Frankfurt, Gutleutstrasse 3.2 km · 3.2 MW
- ColoCenter Frankfurt 3.4 km
- NewColo Frankfurt 3.6 km
- 3U Rechenzentrum Frankfurt 3.6 km
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.