CSCS Piz Daint
CSCS Piz Daint is an operational AI data center operated by ETH Domain in Sarnen, Switzerland. Its power is about 4.4 MW. Epoch AI estimates about 55 H100-equivalent AI chips (NVIDIA Tesla P100 PCIe 16GB).
Key facts
| Status | Operational |
|---|---|
| Operator | ETH Domain |
| Facility power | 4.4 MW Reported (Epoch AI or owner data) |
| AI compute | 55 H100-equivalents |
| AI chips | NVIDIA Tesla P100 PCIe 16GB Reported (Epoch AI or owner data) |
| Chip count | 5,704 Largest reported cluster at this site (Epoch AI). |
| GPU capacity if all AI | about 1,900 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 46.80250, 8.23439 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 220 kV, 5.1 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 1 |
| Power plants within 50 km | 2.2 GW in 52 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 39 g CO₂ per kWh (Switzerland, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 52.3%, nuclear 29.9%, solar 12.1%, oil and other fossil 1.9%, bioenergy 1.6%. Clean power: 97.7% |
Climate and water
| Average temperature | 7.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 31.7 °C (2001 to 2025) |
| Cooling degree days | 60 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.4 kWh per m² per day |
| Wind at 50 m | 3.5 m/s average |
| Water stress today | Low (<10%) (Obwalden) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
GPU clusters at this site
| Cluster | Chips | Count | Power | Since |
|---|---|---|---|---|
| CSCS Piz Daint Phase 1 | NVIDIA Tesla P100 PCIe 16GB | 3,040 | 1.8 MW | 2016-11-01 |
| CSCS Piz Daint Phase 2 | NVIDIA Tesla P100 PCIe 16GB | 5,704 | 4.4 MW | 2017-06-01 |
Source: Epoch AI GPU Clusters.
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does CSCS Piz Daint use?
Public data puts the facility power at about 4.4 MW. Reported (Epoch AI or owner data).
What chips does CSCS Piz Daint use?
Reported chips: NVIDIA Tesla P100 PCIe 16GB.
How close is CSCS Piz Daint to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (220 kV), about 5.1 km away.
How clean is the power for CSCS Piz Daint?
The grid in Switzerland emits about 39 g CO₂ per kWh (2025). Largest sources: hydro 52.3%, nuclear 29.9%, solar 12.1%.
Who operates CSCS Piz Daint?
ETH Domain.
Data centers near Sarnen
- Rechenzentrum Stollen Luzern 27.5 km
- ewl Rechenzentrum Stollen 27.5 km
- CKW DC LuZ Luzern Nord 28.4 km
- ewl Luzern 29.2 km
- 24 hours fiberwork ag 29.3 km
- CKW Colo Wolhusen 30.4 km
- CKW DC Rathausen 31.3 km
- CKW Colo Hochdorf 39.4 km
More ETH Domain data centers
- Alps Supercomputer Switzerland
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.