Data center in Bucaramanga
Data center in Bucaramanga is an operational data center in Bucaramanga, Colombia. Our footprint estimate of its power is about 0.5 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 0.5 MW (range 0.3 MW to 0.8 MW) Estimate from building footprint, low confidence. Footprint estimate: about 430 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 210 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 7.09576, -73.12688 |
Power and grid
| Nearest high-voltage substation | Subestación Eléctrica Real de Minas, 115 kV, 100 m away (ESSA) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Subestación Eléctrica Palenque, 230 kV, 4.2 km away |
| HV substations within 10 km | 8 |
| Power plants within 50 km | 819 MW in 1 plant
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 185 g CO₂ per kWh (Colombia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 68.5%, gas 13%, solar 5.9%, coal 5.5%, oil and other fossil 4.3%. Clean power: 77.1% |
Climate and water
| Average temperature | 20.2 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 33.9 °C (2001 to 2025) |
| Cooling degree days | 949 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.3 kWh per m² per day |
| Wind at 50 m | 1.9 m/s average |
| Water stress today | Low (<10%) (Colombia) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Data center in Bucaramanga use?
We estimate the facility power at about 0.5 MW. Estimate from building footprint, low confidence.
How close is Data center in Bucaramanga to the power grid?
The nearest high-voltage substation in OpenStreetMap is Subestación Eléctrica Real de Minas (115 kV), about 100 m away.
How clean is the power for Data center in Bucaramanga?
The grid in Colombia emits about 185 g CO₂ per kWh (2025). Largest sources: hydro 68.5%, gas 13%, solar 5.9%.