Data center in Wichita Falls

Data center in Wichita Falls is an operational data center in Wichita Falls, United States. Our footprint estimate of its power is about 3.9 MW.

Key facts

StatusOperational
Facility power3.9 MW (range 2 MW to 6.3 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 3,280 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 1,700 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
AddressAirport Drive 2236, 76306, Wichita Falls
Coordinates33.95337, -98.52479

Power and grid

Nearest high-voltage substationUnnamed substation, 138 kV, 2.5 km away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationFisher Road Substation, 345 kV, 11.5 km away
HV substations within 10 km10
UtilitySouthwest Rural Elec Assn INC
Electric retail service territory (HIFLD, US government).
Balancing authoritySWPP
Nearest gas pipelineAtmos Pipeline - Texas, intrastate pipeline, 500 m away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km80 MW in 1 plant
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity343 g CO₂ per kWh (Oklahoma, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 44.6%, wind 41.7%, coal 10.3%, hydro 1.9%, solar 1.1%. Clean power: 45.1%
Industrial power priceUSD 0.082 per kWh (Oklahoma, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature17.9 °C
NASA POWER, average of 2001 to 2025.
Highest temperature45.3 °C (2001 to 2025)
Cooling degree days1,508 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.94 kWh per m² per day
Wind at 50 m6.7 m/s average
Water stress todayLow - Medium (10-20%) (Oklahoma)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Data center in Wichita Falls use?

We estimate the facility power at about 3.9 MW. Estimate from building footprint, low confidence.

How close is Data center in Wichita Falls to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (138 kV), about 2.5 km away. The local utility is Southwest Rural Elec Assn INC, in the SWPP balancing area.

How clean is the power for Data center in Wichita Falls?

The grid in Oklahoma emits about 343 g CO₂ per kWh (2025). Largest sources: gas 44.6%, wind 41.7%, coal 10.3%.