Data Center Portugal Telecom da Covilhã
Data Center Portugal Telecom da Covilhã is an operational data center operated by Portugal Telecom in Covilhã, Portugal. Our footprint estimate of its power is about 15 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Portugal Telecom |
| Facility power | 15 MW (range 7.5 MW to 24 MW) Estimate from building footprint, low confidence. Footprint estimate: about 4,171 m² building outline x 3 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 6,400 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 40.26548, -7.47952 |
Power and grid
| Nearest high-voltage substation | Subestação de Ferro, 220 kV, 3.4 km away (REN) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 2 |
| Power plants within 50 km | 574 MW in 30 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 128 g CO₂ per kWh (Portugal, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 29.7%, wind 26.8%, solar 17.3%, gas 16.5%, bioenergy 6.6%. Clean power: 80.9% |
| Industrial power price | EUR 0.090 per kWh (Portugal, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 12.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.5 °C (2001 to 2025) |
| Cooling degree days | 380 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.59 kWh per m² per day |
| Wind at 50 m | 5.3 m/s average |
| Water stress today | Low - Medium (10-20%) (Castelo Branco) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Data Center Portugal Telecom da Covilhã use?
We estimate the facility power at about 15 MW. Estimate from building footprint, low confidence.
How close is Data Center Portugal Telecom da Covilhã to the power grid?
The nearest high-voltage substation in OpenStreetMap is Subestação de Ferro (220 kV), about 3.4 km away.
How clean is the power for Data Center Portugal Telecom da Covilhã?
The grid in Portugal emits about 128 g CO₂ per kWh (2025). Largest sources: hydro 29.7%, wind 26.8%, solar 17.3%.
Who operates Data Center Portugal Telecom da Covilhã?
Portugal Telecom.
Sources
Correct this page or get the data