Data Felix DF01
Data Felix DF01 is an operational data center operated by Data Felix in Caserta, Italy. Our footprint estimate of its power is about 2.6 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Data Felix |
| Facility power | 2.6 MW (range 1.3 MW to 4.2 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,090 m² building outline x 2 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 1,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 8 networks, 3 internet exchanges PeeringDB. |
| Address | Viale Enrico Mattei |
| Coordinates | 41.06640, 14.32144 |
| Website | datafelix.it |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 150 kV, 200 m away (e-distribuzione S.p.A.) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 220 kV, 2.7 km away |
| HV substations within 10 km | 18 |
| Power plants within 50 km | 2.8 GW in 7 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 285 g CO₂ per kWh (Italy, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 47.4%, solar 16.8%, hydro 15.7%, wind 8.1%, bioenergy 5.9%. Clean power: 48.7% |
| Industrial power price | EUR 0.173 per kWh (Italy, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 15.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.7 °C (2001 to 2025) |
| Cooling degree days | 758 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.22 kWh per m² per day |
| Wind at 50 m | 4 m/s average |
| Water stress today | Extremely High (>80%) (Campania) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Data Felix DF01 use?
We estimate the facility power at about 2.6 MW. Estimate from building footprint, low confidence.
How close is Data Felix DF01 to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (150 kV), about 200 m away.
How clean is the power for Data Felix DF01?
The grid in Italy emits about 285 g CO₂ per kWh (2025). Largest sources: gas 47.4%, solar 16.8%, hydro 15.7%.
Who operates Data Felix DF01?
Data Felix.
Data centers near Caserta
- Archivio di Stato di Caserta 2.6 km
- Belvedere DC 14.7 km
- TIM Opb Nola 22.0 km
- Namex Napoli - Università Parthenope 26.8 km
- Arpac 38.2 km
- Positivo Salerno 62.4 km
Sources