DataCentre220
DataCentre220 is an operational data center operated by Data Centre in Auckland, New Zealand. Our footprint estimate of its power is about 5 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Data Centre |
| Facility power | 5 MW (range 2.5 MW to 7.9 MW) Estimate from building footprint, low confidence. Footprint estimate: about 688 m² building outline x 6 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 97 networks, 6 internet exchanges PeeringDB. |
| Also known as | Data Centre 220 |
| Address | 220 Queen Street, Auckland Central |
| Opened | 1962 |
| Coordinates | -36.84935, 174.76541 |
| Website | datacentre.co.nz |
Power and grid
| Grid carbon intensity | 96 g CO₂ per kWh (New Zealand, 2025) Average of all power made in the area. Ember. |
|---|---|
| Grid power mix | hydro 53.7%, other renewables 22%, wind 9.5%, gas 8.6%, solar 1.8%. Clean power: 88.2% |
Climate and water
| Average temperature | 15.7 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 28.2 °C (2001 to 2025) |
| Cooling degree days | 192 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.4 kWh per m² per day |
| Wind at 50 m | 7.2 m/s average |
| Water stress today | Low (<10%) (Auckland) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does DataCentre220 use?
We estimate the facility power at about 5 MW. Estimate from building footprint, low confidence.
How clean is the power for DataCentre220?
The grid in New Zealand emits about 96 g CO₂ per kWh (2025). Largest sources: hydro 53.7%, other renewables 22%, wind 9.5%.
Who operates DataCentre220?
Data Centre.
Data centers near Auckland
- 191 Queen Street 97 m
- TVC 443 m
- Mayoral Drive Exchange (MDR) 561 m · 18 MW
- Airedale Exchange 652 m · 14 MW
- ICONZ House 701 m
- Data Vault Auckland Data Center 1.6 km · 2 MW
- Chorus Ponsonby Exchange (POY) 1.9 km
- Chorus Mount Eden Exchange (MOD) 3.7 km
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.