EBRC Resilience Centre Luxembourg East
EBRC Resilience Centre Luxembourg East is an operational data center in Grevenmacher, Luxembourg. Our footprint estimate of its power is about 8.5 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 8.5 MW (range 4.2 MW to 14 MW) Estimate from building footprint, low confidence. Footprint estimate: about 7,064 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,600 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 49.69401, 6.32465 |
Power and grid
| Nearest high-voltage substation | Heisdorf, 220 kV, 13.6 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Power plants within 50 km | 7.0 GW in 55 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 111 g CO₂ per kWh (Luxembourg, 2025) Average of all power made in the area. Ember. |
| Grid power mix | solar 37.4%, wind 27.1%, bioenergy 23.4%, hydro 4.4%, oil and other fossil 4%. Clean power: 92.3% |
| Industrial power price | EUR 0.104 per kWh (Luxembourg, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.7 °C (2001 to 2025) |
| Cooling degree days | 137 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.15 kWh per m² per day |
| Wind at 50 m | 6 m/s average |
| Water stress today | Medium - High (20-40%) (Grevenmacher) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does EBRC Resilience Centre Luxembourg East use?
We estimate the facility power at about 8.5 MW. Estimate from building footprint, low confidence.
How close is EBRC Resilience Centre Luxembourg East to the power grid?
The nearest high-voltage substation in OpenStreetMap is Heisdorf (220 kV), about 13.6 km away.
How clean is the power for EBRC Resilience Centre Luxembourg East?
The grid in Luxembourg emits about 111 g CO₂ per kWh (2025). Largest sources: solar 37.4%, wind 27.1%, bioenergy 23.4%.
Data centers near Grevenmacher
- DEEP Resilience Center Luxembourg East 219 m
- BCE Colocation Luxembourg 13.2 km
- Visual Online Contern 13.2 km · 0.5 MW
- Verizon Luxembourg 13.4 km · 3.5 MW
- European Business Reliance Centre (EBRC) 19.5 km
- SecureIT DCC 19.5 km
- EuroHPC MeluXina 19.7 km · 0.7 MW
- Portus LUX1 20.0 km