EDF data center in Val-de-Reuil
EDF data center in Val-de-Reuil is an operational data center operated by EDF in Val-de-Reuil, France. Our footprint estimate of its power is about 15 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | EDF |
| Facility power | 15 MW (range 5.9 MW to 37 MW) Estimate from building footprint, low confidence. Footprint estimate: about 123,716 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 6,400 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 49.26338, 1.18516 |
Power and grid
| Nearest high-voltage substation | Poste électrique du Manoir, 225 kV, 6.5 km away (RTE) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 1 |
| Power plants within 50 km | 419 MW in 15 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 41 g CO₂ per kWh (France, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 68.3%, hydro 10.3%, wind 8.8%, solar 5.6%, gas 3%. Clean power: 94.9% |
| Industrial power price | EUR 0.098 per kWh (France, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 36.3 °C (2001 to 2025) |
| Cooling degree days | 58 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.2 kWh per m² per day |
| Wind at 50 m | 6.7 m/s average |
| Water stress today | Low - Medium (10-20%) (France) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does EDF data center in Val-de-Reuil use?
We estimate the facility power at about 15 MW. Estimate from building footprint, low confidence.
How close is EDF data center in Val-de-Reuil to the power grid?
The nearest high-voltage substation in OpenStreetMap is Poste électrique du Manoir (225 kV), about 6.5 km away.
How clean is the power for EDF data center in Val-de-Reuil?
The grid in France emits about 41 g CO₂ per kWh (2025). Largest sources: nuclear 68.3%, hydro 10.3%, wind 8.8%.
Who operates EDF data center in Val-de-Reuil?
EDF.
Data centers near Val-de-Reuil
- SFR 1.3 km · 3.2 MW
- Datacenter BNP 2.6 km · 3.6 MW
- Bouygues Télécom data center in Petit-Couronne 17.1 km · 0.6 MW
- Cogent Rouen 20.0 km · 0.7 MW
- Data center in Rouen 20.4 km · 1.7 MW
- PoP Faraday (Rouen) 21.4 km
- Ultraedge Canteleu 23.3 km
- Datacenter EDF 32.0 km · 13 MW
More EDF data centers
- Datacenter EDF France
- Datacenter EDF France