EVB-CLJ-DC1
EVB-CLJ-DC1 is an operational data center operated by Evobits Information Technology in Juc-Herghelie, Romania. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Evobits Information Technology |
| Networks | 1 networks PeeringDB. |
| Address | Parcul Industrial Tetarom III, TRC-Park, Hala C1 |
| Coordinates | 46.88115, 23.79025 |
| Website | evobitsit.com |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 110 kV, 2.5 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Gadalin Substation, 400 kV, 8.7 km away |
| HV substations within 10 km | 2 |
| Power plants within 50 km | 133 MW in 9 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 259 g CO₂ per kWh (Romania, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 24.2%, nuclear 20.5%, gas 16.9%, coal 15.1%, wind 12%. Clean power: 67.6% |
| Industrial power price | EUR 0.160 per kWh (Romania, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.2 °C (2001 to 2025) |
| Cooling degree days | 303 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.35 kWh per m² per day |
| Wind at 50 m | 4.6 m/s average |
| Water stress today | Low - Medium (10-20%) (Romania) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is EVB-CLJ-DC1 to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (110 kV), about 2.5 km away.
How clean is the power for EVB-CLJ-DC1?
The grid in Romania emits about 259 g CO₂ per kWh (2025). Largest sources: hydro 24.2%, nuclear 20.5%, gas 16.9%.
Who operates EVB-CLJ-DC1?
Evobits Information Technology.
Data centers near Juc-Herghelie
- efectRO DC1 17.3 km
- GTS Telecom DC Cluj-Napoca 18.3 km
- DataWave#1 18.4 km
- Starnet Media Cluj-Napoca 19.3 km
- Compania de Informatica Aplicata 20.3 km
- Hosting Data Center Cluj 22.7 km