GAD-Rechenzentrum 2

GAD-Rechenzentrum 2 is an operational data center operated by Atruvia in Münster, Germany. Our footprint estimate of its power is about 14 MW.

Key facts

StatusOperational
OperatorAtruvia
Facility power14 MW (range 7.2 MW to 23 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 11,992 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 6,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
AddressStockholmer Straße 11, 48163, Münster
Opened2016
Coordinates51.89347, 7.59630

Power and grid

Nearest high-voltage substationAmelsbüren, 220 kV, 900 m away (Amprion)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km9
Power plants within 50 km6.2 GW in 33 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity334 g CO₂ per kWh (Germany, 2025)
Average of all power made in the area. Ember.
Grid power mixwind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5%
Industrial power priceEUR 0.146 per kWh (Germany, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature9.9 °C
NASA POWER, average of 2001 to 2025.
Highest temperature37.4 °C (2001 to 2025)
Cooling degree days105 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.9 kWh per m² per day
Wind at 50 m6.7 m/s average
Water stress todayMedium - High (20-40%) (Germany)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does GAD-Rechenzentrum 2 use?

We estimate the facility power at about 14 MW. Estimate from building footprint, low confidence.

How close is GAD-Rechenzentrum 2 to the power grid?

The nearest high-voltage substation in OpenStreetMap is Amelsbüren (220 kV), about 900 m away.

How clean is the power for GAD-Rechenzentrum 2?

The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.

Who operates GAD-Rechenzentrum 2?

Atruvia.