GDS Shanghai Data Center

GDS Shanghai Data Center is an operational data center in Jinqiao, China. Our footprint estimate of its power is about 76 MW. Likely chips: Huawei Ascend and NVIDIA China-market GPUs (guess).

Key facts

StatusOperational
Facility power76 MW (range 38 MW to 122 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 63,489 m² building outline x 1 floor(s) x 1.2 kW/m².
AI chipsHuawei Ascend and NVIDIA China-market GPUs
Guess from the operator, not confirmed. Chinese operators use Huawei Ascend and export-limited NVIDIA chips.
GPU capacity if all AIabout 32,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Coordinates31.32305, 121.60015

Power and grid

Nearest high-voltage substation外高桥第三发电厂500千伏升压站, 500 kV, 2.9 km away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km5
Power plants within 50 km24 GW in 21 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity528 g CO₂ per kWh (China, 2025)
Average of all power made in the area. Ember.
Grid power mixcoal 54.8%, hydro 13.3%, solar 11.2%, wind 10.7%, nuclear 4.6%. Clean power: 41.1%

Climate and water

Average temperature16.6 °C
NASA POWER, average of 2001 to 2025.
Highest temperature39 °C (2001 to 2025)
Cooling degree days1,138 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.74 kWh per m² per day
Wind at 50 m6.4 m/s average
Water stress todayHigh (40-80%) (Shanghai)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050High (40-80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does GDS Shanghai Data Center use?

We estimate the facility power at about 76 MW. Estimate from building footprint, low confidence.

What chips does GDS Shanghai Data Center use?

No chips are reported. Based on the operator, the likely chips are Huawei Ascend and NVIDIA China-market GPUs.

How close is GDS Shanghai Data Center to the power grid?

The nearest high-voltage substation in OpenStreetMap is 外高桥第三发电厂500千伏升压站 (500 kV), about 2.9 km away.

How clean is the power for GDS Shanghai Data Center?

The grid in China emits about 528 g CO₂ per kWh (2025). Largest sources: coal 54.8%, hydro 13.3%, solar 11.2%.

Data centers near Jinqiao

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.