Ikoula IKDC1
Ikoula IKDC1 is an operational data center operated by Ikoula Net in Reims, France. Our footprint estimate of its power is about 1.3 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Ikoula Net |
| Facility power | 1.3 MW (range 0.6 MW to 2.1 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,074 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 560 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 8 networks PeeringDB. |
| Also known as | Ikoula Data Center |
| Address | 32, rue du Pont Assy |
| Coordinates | 49.23382, 4.03450 |
| Website | ikoula.com |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 225 kV, 3.7 km away (Enedis) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 5 |
| Power plants within 50 km | 383 MW in 10 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 41 g CO₂ per kWh (France, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 68.3%, hydro 10.3%, wind 8.8%, solar 5.6%, gas 3%. Clean power: 94.9% |
| Industrial power price | EUR 0.098 per kWh (France, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 41.5 °C (2001 to 2025) |
| Cooling degree days | 142 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.15 kWh per m² per day |
| Wind at 50 m | 6.1 m/s average |
| Water stress today | Medium - High (20-40%) (Grand Est) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Ikoula IKDC1 use?
We estimate the facility power at about 1.3 MW. Estimate from building footprint, low confidence.
How close is Ikoula IKDC1 to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (225 kV), about 3.7 km away.
How clean is the power for Ikoula IKDC1?
The grid in France emits about 41 g CO₂ per kWh (2025). Largest sources: nuclear 68.3%, hydro 10.3%, wind 8.8%.
Who operates Ikoula IKDC1?
Ikoula Net.
Data centers near Reims
- Hexanet - DC Roland 2.1 km · 1.1 MW
- Neuf Reims 3.0 km
- Bouygues Télécom data center in Reims 5.0 km · 1.2 MW
- Ikoula IKDC2 42.0 km
More Ikoula Net data centers
- Ikoula IKDC2 France