KR1 강남데이터센터
KR1 강남데이터센터 is an operational data center operated by 엠피리온 디지털 in Seongnam-si, South Korea. Our footprint estimate of its power is about 20 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | 엠피리온 디지털 |
| Facility power | 20 MW (range 10 MW to 33 MW) Estimate from building footprint, low confidence. Footprint estimate: about 2,821 m² building outline x 6 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 8,500 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 37.45811, 127.03783 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 154 kV, 1.1 km away (한국전력공사) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 345 kV, 3.1 km away |
| HV substations within 10 km | 37 |
| Power plants within 50 km | 21 GW in 51 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 418 g CO₂ per kWh (South Korea, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 31.1%, nuclear 29.4%, gas 28%, solar 6%, bioenergy 3.2%. Clean power: 39.9% |
Climate and water
| Average temperature | 11.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 35.4 °C (2001 to 2025) |
| Cooling degree days | 551 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.81 kWh per m² per day |
| Wind at 50 m | 5.3 m/s average |
| Water stress today | Medium - High (20-40%) (Gyeonggi-do) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does KR1 강남데이터센터 use?
We estimate the facility power at about 20 MW. Estimate from building footprint, low confidence.
How close is KR1 강남데이터센터 to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (154 kV), about 1.1 km away.
How clean is the power for KR1 강남데이터센터?
The grid in South Korea emits about 418 g CO₂ per kWh (2025). Largest sources: coal 31.1%, nuclear 29.4%, gas 28%.
Who operates KR1 강남데이터센터?
엠피리온 디지털.
Data centers near Seongnam-si
- LG Uplus SEOCHO1 IDC 3.1 km
- Pacnet SEDS1 3.5 km
- KINX Dogok 3.5 km
- Digital Edge SEL1 - Seoul 4.7 km
- kt cloud Gangnam 5.2 km
- LG Uplus Nonhyun IDC 5.9 km
- KINX Pyeongchon 8.9 km
- KINX Bundang 9.1 km
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.