Prescient Data Centres Northern Ireland
Prescient Data Centres Northern Ireland is an operational data center operated by Prescient Data Centres Northern Ireland in Coleraine, United Kingdom. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Prescient Data Centres Northern Ireland |
| Networks | 1 networks PeeringDB. |
| Address | Atlantic Link Enterprise Campus, Portstewart Rd |
| Coordinates | 55.14668, -6.67615 |
| Website | prescientdc.com |
Power and grid
| Nearest high-voltage substation | Loguestown 110kV Substation, 110 kV, 1.3 km away (NIE Networks) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Coolkeeragh 275 kV Substation, 275 kV, 38.1 km away |
| HV substations within 10 km | 2 |
| Power plants within 50 km | 195 MW in 9 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 218 g CO₂ per kWh (United Kingdom, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 31.3%, wind 29.4%, bioenergy 13.9%, nuclear 12.4%, solar 6.6%. Clean power: 64.2% |
Climate and water
| Average temperature | 9.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 23.8 °C (2001 to 2025) |
| Cooling degree days | 0 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.59 kWh per m² per day |
| Wind at 50 m | 8.3 m/s average |
| Water stress today | Low (<10%) (Northern Ireland) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Prescient Data Centres Northern Ireland to the power grid?
The nearest high-voltage substation in OpenStreetMap is Loguestown 110kV Substation (110 kV), about 1.3 km away.
How clean is the power for Prescient Data Centres Northern Ireland?
The grid in United Kingdom emits about 218 g CO₂ per kWh (2025). Largest sources: gas 31.3%, wind 29.4%, bioenergy 13.9%.
Who operates Prescient Data Centres Northern Ireland?
Prescient Data Centres Northern Ireland.
Data centers near Coleraine
- Prescient Coleraine 957 m · 10 MW