Rowan Green Data data center in Hermiston

Rowan Green Data data center in Hermiston is an operational data center operated by Rowan Green Data in Hermiston, United States. Our footprint estimate of its power is about 144 MW.

Key facts

StatusOperational
OperatorRowan Green Data
Facility power144 MW (range 58 MW to 361 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 1,202,923 m² site outline x 0.12 kW per m² of land.
GPU capacity if all AIabout 62,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Also known asPercheron DC
Coordinates45.71041, -119.82348
Websiterowan.digital/portfolio/percheron

Power and grid

Nearest high-voltage substationGrassland Switchyard, 500 kV, 1.8 km away (Portland General Electric)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km2
UtilityBonneville Power Administration (federal)
Electric retail service territory (HIFLD, US government).
Balancing authorityBPAT
Nearest gas pipelineGas Transmission - Northwest, interstate pipeline, 17.1 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km3.9 GW in 15 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity200 g CO₂ per kWh (Oregon, 2025)
Average of all power made in the area. Ember.
Grid power mixhydro 44.6%, gas 33.9%, wind 14.5%, solar 5.2%, bioenergy 1.6%. Clean power: 66.2%
Industrial power priceUSD 0.087 per kWh (Oregon, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature11.4 °C
NASA POWER, average of 2001 to 2025.
Highest temperature41.8 °C (2001 to 2025)
Cooling degree days399 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.22 kWh per m² per day
Wind at 50 m6.1 m/s average
Water stress todayLow - Medium (10-20%) (Oregon)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Rowan Green Data data center in Hermiston use?

We estimate the facility power at about 144 MW. Estimate from building footprint, low confidence.

How close is Rowan Green Data data center in Hermiston to the power grid?

The nearest high-voltage substation in OpenStreetMap is Grassland Switchyard (500 kV), about 1.8 km away. The local utility is Bonneville Power Administration, in the BPAT balancing area.

How clean is the power for Rowan Green Data data center in Hermiston?

The grid in Oregon emits about 200 g CO₂ per kWh (2025). Largest sources: hydro 44.6%, gas 33.9%, wind 14.5%.

Who operates Rowan Green Data data center in Hermiston?

Rowan Green Data.

Data centers near Hermiston

More Rowan Green Data data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.