SLT IDC - National Data Center - Pitipana
SLT IDC - National Data Center - Pitipana is an operational data center operated by Sri Lanka Telecom in Pitipana, Sri Lanka. Our footprint estimate of its power is about 3.4 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Sri Lanka Telecom |
| Facility power | 3.4 MW (range 1.7 MW to 5.5 MW) Estimate from building footprint, low confidence. Footprint estimate: about 2,873 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 1,500 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Dampe Road, 10206, Pitipana |
| Coordinates | 6.82455, 80.03663 |
Power and grid
| Nearest high-voltage substation | Padukka Grid Substation, 220 kV, 6.3 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 2 |
| Power plants within 50 km | 1.6 GW in 13 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 352 g CO₂ per kWh (Sri Lanka, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 41.5%, coal 28.9%, solar 13.2%, oil and other fossil 12.7%, wind 2.4%. Clean power: 58.4% |
Climate and water
| Average temperature | 26.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 35.5 °C (2001 to 2025) |
| Cooling degree days | 3,055 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.19 kWh per m² per day |
| Wind at 50 m | 5.5 m/s average |
| Water stress today | Medium - High (20-40%) (Sri Lanka) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does SLT IDC - National Data Center - Pitipana use?
We estimate the facility power at about 3.4 MW. Estimate from building footprint, low confidence.
How close is SLT IDC - National Data Center - Pitipana to the power grid?
The nearest high-voltage substation in OpenStreetMap is Padukka Grid Substation (220 kV), about 6.3 km away.
How clean is the power for SLT IDC - National Data Center - Pitipana?
The grid in Sri Lanka emits about 352 g CO₂ per kWh (2025). Largest sources: hydro 41.5%, coal 28.9%, solar 13.2%.
Who operates SLT IDC - National Data Center - Pitipana?
Sri Lanka Telecom.
Data centers near Pitipana
- Lanka Bell Limited 22.6 km