STTelemedia Global Data Centeres
STTelemedia Global Data Centeres is an operational data center in Bengaluru, India. Our footprint estimate of its power is about 45 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 45 MW (range 22 MW to 72 MW) Estimate from building footprint, low confidence. Footprint estimate: about 6,236 m² building outline x 6 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 19,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 12.98123, 77.71998 |
Power and grid
| Nearest high-voltage substation | EPIP Whitefield Substation, 220 kV, 500 m away (KPTCL) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 11 |
| Power plants within 50 km | 370 MW in 1 plant
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 666 g CO₂ per kWh (India, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 70%, solar 9.8%, hydro 8.5%, wind 5%, nuclear 2.6%. Clean power: 27.1% |
Climate and water
| Average temperature | 23.7 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.4 °C (2001 to 2025) |
| Cooling degree days | 2,222 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.61 kWh per m² per day |
| Wind at 50 m | 5.8 m/s average |
| Water stress today | High (40-80%) (Karnataka) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does STTelemedia Global Data Centeres use?
We estimate the facility power at about 45 MW. Estimate from building footprint, low confidence.
How close is STTelemedia Global Data Centeres to the power grid?
The nearest high-voltage substation in OpenStreetMap is EPIP Whitefield Substation (220 kV), about 500 m away.
How clean is the power for STTelemedia Global Data Centeres?
The grid in India emits about 666 g CO₂ per kWh (2025). Largest sources: coal 70%, solar 9.8%, hydro 8.5%.
Data centers near Bengaluru
- Nxtra Data Bangalore DC 1 588 m
- STTGDC BLR1 614 m
- Web Werks Bangalore 1 2.4 km
- Netmagic Bangalore DC03 7.6 km · 1.5 MW
- Infynix Bengaluru 11.5 km
- Bell Teleservices India Pvt Ltd 12.0 km
- Ishan Technologies Bengaluru 12.4 km
- CtrlS Bangalore DC1 13.8 km