Vegacom DC
Vegacom DC is an operational data center operated by Vegacom in Praha 9 – Střížkov, Czechia. Our footprint estimate of its power is about 8.9 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Vegacom |
| Facility power | 8.9 MW (range 4.5 MW to 14 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,860 m² building outline x 4 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,800 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 5 networks PeeringDB. |
| Also known as | DC Vega |
| Address | Teplická 17 |
| Coordinates | 50.12563, 14.48579 |
| Website | dcvega.cz |
Power and grid
| Nearest high-voltage substation | Praha východ, 110 kV, 2.3 km away (Pražská energetika) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Rozvodna Malešice, 220 kV, 5.6 km away |
| HV substations within 10 km | 14 |
| Power plants within 50 km | 1.8 GW in 23 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 401 g CO₂ per kWh (Czechia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 42.3%, coal 35.2%, bioenergy 8%, solar 5.8%, gas 5.4%. Clean power: 59.2% |
| Industrial power price | EUR 0.154 per kWh (Czechia, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 8.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 38 °C (2001 to 2025) |
| Cooling degree days | 181 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.97 kWh per m² per day |
| Wind at 50 m | 6 m/s average |
| Water stress today | Low (<10%) (Prague) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Vegacom DC use?
We estimate the facility power at about 8.9 MW. Estimate from building footprint, low confidence.
How close is Vegacom DC to the power grid?
The nearest high-voltage substation in OpenStreetMap is Praha východ (110 kV), about 2.3 km away.
How clean is the power for Vegacom DC?
The grid in Czechia emits about 401 g CO₂ per kWh (2025). Largest sources: nuclear 42.3%, coal 35.2%, bioenergy 8%.
Who operates Vegacom DC?
Vegacom.
Data centers near Praha 9 – Střížkov
- SafeDX s.r.o. 3.0 km · 3.5 MW
- Connect plus s.r.o. 4.0 km
- Státní pokladna Centrum sdílených služeb, s. p. 4.0 km
- GTS Nagano Prague 4.7 km
- GTS Telehouse Prague 5.3 km
- DC Coolhousing - Prague 5.3 km
- UPL TELECOM s.r.o. 5.4 km
- DC Tower Zizkov CRa 5.5 km · 17 MW