AdaniConneX Chennai 1
AdaniConneX Chennai 1 is an operational data center in Nāvalūr, India. Our footprint estimate of its power is about 4.1 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 4.1 MW (range 2 MW to 6.5 MW) Estimate from building footprint, low confidence. Footprint estimate: about 3,410 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 1,800 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 12.82159, 80.22611 |
Power and grid
| Nearest high-voltage substation | Siruseri, 230 kV, 1.7 km away (TANTRANSCO) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 6 |
| Power plants within 50 km | 4.3 GW in 5 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 666 g CO₂ per kWh (India, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 70%, solar 9.8%, hydro 8.5%, wind 5%, nuclear 2.6%. Clean power: 27.1% |
Climate and water
| Average temperature | 28 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 42.7 °C (2001 to 2025) |
| Cooling degree days | 3,708 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.22 kWh per m² per day |
| Wind at 50 m | 5.3 m/s average |
| Water stress today | Extremely High (>80%) (Tamil Nadu) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does AdaniConneX Chennai 1 use?
We estimate the facility power at about 4.1 MW. Estimate from building footprint, low confidence.
How close is AdaniConneX Chennai 1 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Siruseri (230 kV), about 1.7 km away.
How clean is the power for AdaniConneX Chennai 1?
The grid in India emits about 666 g CO₂ per kWh (2025). Largest sources: coal 70%, solar 9.8%, hydro 8.5%.
Data centers near Nāvalūr
- AdaniConneX Chennai 1 884 m
- Nxtra Data Chennai 1.1 km · 1.2 MW
- Nxtra Data Chennai DC 1 2.7 km
- Data center in Sholinganallur 5.5 km
- Sify Tidel-DC- Chennai 18.8 km
- MilkyUpizise 20.5 km
- Government Data Centre 21.9 km · 6.2 MW
- Bharti Airtel Santhome 23.3 km