Airbus data center in Élancourt is an operational data center operated by Airbus in Élancourt, France. Our footprint estimate of its power is about 17 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Airbus |
| Facility power | 17 MW (range 8.7 MW to 28 MW) Estimate from building footprint, low confidence. Footprint estimate: about 14,498 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 7,300 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 48.79767, 1.96937 |
Power and grid
| Nearest high-voltage substation | Poste électrique de la Vérinnerie, 225 kV, 2.1 km away (RTE) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 3 |
| Power plants within 50 km | 1.2 GW in 39 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 41 g CO₂ per kWh (France, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 68.3%, hydro 10.3%, wind 8.8%, solar 5.6%, gas 3%. Clean power: 94.9% |
| Industrial power price | EUR 0.098 per kWh (France, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 38.2 °C (2001 to 2025) |
| Cooling degree days | 106 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.19 kWh per m² per day |
| Wind at 50 m | 6.4 m/s average |
| Water stress today | Low - Medium (10-20%) (France) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Airbus data center in Élancourt use?
We estimate the facility power at about 17 MW. Estimate from building footprint, low confidence.
How close is Airbus data center in Élancourt to the power grid?
The nearest high-voltage substation in OpenStreetMap is Poste électrique de la Vérinnerie (225 kV), about 2.1 km away.
How clean is the power for Airbus data center in Élancourt?
The grid in France emits about 41 g CO₂ per kWh (2025). Largest sources: nuclear 68.3%, hydro 10.3%, wind 8.8%.
Who operates Airbus data center in Élancourt?
Airbus.
Data centers near Élancourt
- Datacenter Thales Nungesser 865 m
- Dataxion France DTX01 1.1 km
- Allianz data center in Élancourt 1.3 km · 7.3 MW
- Site technique SFR 4.1 km · 2.9 MW
- Site technique SFR 4.3 km · 3.7 MW
- Groupe Cyllene - DC - Montigny les Bretonneux 4.4 km
- Datacenter Bouygues Télécom 4.9 km · 9.8 MW
- Datacenter RTE 5.9 km
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.