conova - Datacenter 6/7
conova - Datacenter 6/7 is an operational data center operated by conova communications in Hallein, Austria. Our footprint estimate of its power is about 1.6 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | conova communications |
| Facility power | 1.6 MW (range 0.8 MW to 2.6 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,333 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 680 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 1 networks, 1 internet exchanges PeeringDB. |
| Also known as | Conova Communications |
| Address | Solvay-Halvic-Strasse 70 |
| Coordinates | 47.70616, 13.08283 |
| Website | conova.com |
Power and grid
| Nearest high-voltage substation | Umspannwerk Oberalm, 110 kV, 100 m away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Salzach Stich, 220 kV, 14.4 km away |
| HV substations within 10 km | 4 |
| Power plants within 50 km | 440 MW in 21 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 117 g CO₂ per kWh (Austria, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 51.9%, solar 14.1%, gas 11.9%, wind 11.4%, bioenergy 6.3%. Clean power: 83.6% |
| Industrial power price | EUR 0.150 per kWh (Austria, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 5.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 37 °C (2001 to 2025) |
| Cooling degree days | 30 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.25 kWh per m² per day |
| Wind at 50 m | 2.6 m/s average |
| Water stress today | Low (<10%) (Salzburg) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does conova - Datacenter 6/7 use?
We estimate the facility power at about 1.6 MW. Estimate from building footprint, low confidence.
How close is conova - Datacenter 6/7 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Oberalm (110 kV), about 100 m away.
How clean is the power for conova - Datacenter 6/7?
The grid in Austria emits about 117 g CO₂ per kWh (2025). Largest sources: hydro 51.9%, solar 14.1%, gas 11.9%.
Who operates conova - Datacenter 6/7?
conova communications.
Data centers near Hallein
- conova - Datacenter 4/5 11.0 km
- Techno-Z 13.3 km
- STACKIT Ostermiething (DC10) 40.6 km · 7.5 MW
More conova communications data centers
- conova - Datacenter 4/5 Austria
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.