CSquare London LHR3

CSquare London LHR3 is an operational data center operated by CSquare in Lower Earley, United Kingdom. Our footprint estimate of its power is about 20 MW.

Key facts

StatusOperational
OperatorCSquare
Facility power20 MW (range 9.9 MW to 32 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 8,214 m² building outline x 2 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 8,500 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Coordinates51.43735, -0.88738

Power and grid

Nearest high-voltage substationReading Main Substation, 132 kV, 3.6 km away (Scottish and Southern Electricity Networks)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationBramley Substation, 400 kV, 17.3 km away
HV substations within 10 km7
Power plants within 50 km3.0 GW in 78 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity218 g CO₂ per kWh (United Kingdom, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 31.3%, wind 29.4%, bioenergy 13.9%, nuclear 12.4%, solar 6.6%. Clean power: 64.2%

Climate and water

Average temperature10.1 °C
NASA POWER, average of 2001 to 2025.
Highest temperature35.5 °C (2001 to 2025)
Cooling degree days44 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.94 kWh per m² per day
Wind at 50 m7.2 m/s average
Water stress todayLow - Medium (10-20%) (England)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does CSquare London LHR3 use?

We estimate the facility power at about 20 MW. Estimate from building footprint, low confidence.

How close is CSquare London LHR3 to the power grid?

The nearest high-voltage substation in OpenStreetMap is Reading Main Substation (132 kV), about 3.6 km away.

How clean is the power for CSquare London LHR3?

The grid in United Kingdom emits about 218 g CO₂ per kWh (2025). Largest sources: gas 31.3%, wind 29.4%, bioenergy 13.9%.

Who operates CSquare London LHR3?

CSquare.