DartPoints Columbus, IN - CLU1

DartPoints Columbus, IN - CLU1 is an operational data center operated by DartPoints in Columbus, United States. Our footprint estimate of its power is about 1.7 MW.

Key facts

StatusOperational
OperatorDartPoints
Facility power1.7 MW (range 0.7 MW to 4.3 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 14,194 m² site outline x 0.12 kW per m² of land.
GPU capacity if all AIabout 730 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks7 networks
PeeringDB.
Also known asDartPoints Columbus
Address2425 Technology Boulevard
Coordinates39.18254, -85.89735
Websitedartpoints.com/locations/columbus

Power and grid

Nearest high-voltage substationColumbus Substation (345kV), 345 kV, 2.6 km away (Duke Energy)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km3
UtilityBartholomew County Rural E M C (cooperative)
Electric retail service territory (HIFLD, US government).
Balancing authorityMISO
Nearest gas pipelineTexas Gas Transmission Co, interstate pipeline, 10.1 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km9 MW in 3 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity643 g CO₂ per kWh (Indiana, 2025)
Average of all power made in the area. Ember.
Grid power mixcoal 44.7%, gas 36.1%, wind 9.4%, solar 6.5%, oil and other fossil 2.8%. Clean power: 16.4%
Industrial power priceUSD 0.093 per kWh (Indiana, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature12.2 °C
NASA POWER, average of 2001 to 2025.
Highest temperature41.3 °C (2001 to 2025)
Cooling degree days670 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.99 kWh per m² per day
Wind at 50 m5.1 m/s average
Water stress todayMedium - High (20-40%) (Indiana)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does DartPoints Columbus, IN - CLU1 use?

We estimate the facility power at about 1.7 MW. Estimate from building footprint, low confidence.

How close is DartPoints Columbus, IN - CLU1 to the power grid?

The nearest high-voltage substation in OpenStreetMap is Columbus Substation (345kV) (345 kV), about 2.6 km away. The local utility is Bartholomew County Rural E M C, in the MISO balancing area.

How clean is the power for DartPoints Columbus, IN - CLU1?

The grid in Indiana emits about 643 g CO₂ per kWh (2025). Largest sources: coal 44.7%, gas 36.1%, wind 9.4%.

Who operates DartPoints Columbus, IN - CLU1?

DartPoints.

Data centers near Columbus

More DartPoints data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.