Datahouse
Datahouse is an operational data center in Presnenskiy, Russia. Our footprint estimate of its power is about 3.9 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 3.9 MW (range 1.9 MW to 6.2 MW) Estimate from building footprint, low confidence. Footprint estimate: about 3,229 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 1,700 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | 1-я Магистральная улица 12 |
| Coordinates | 55.76973, 37.52450 |
Power and grid
| Nearest high-voltage substation | Магистральная, 220 kV, 900 m away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 86 |
| Power plants within 50 km | 13 GW in 26 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 447 g CO₂ per kWh (Russia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 45.6%, nuclear 18.3%, coal 17.7%, hydro 16.7%, oil and other fossil 1%. Clean power: 35.7% |
Climate and water
| Average temperature | 4.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 35.1 °C (2001 to 2025) |
| Cooling degree days | 86 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.8 kWh per m² per day |
| Wind at 50 m | 6.5 m/s average |
| Water stress today | Low - Medium (10-20%) (Russia) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Datahouse use?
We estimate the facility power at about 3.9 MW. Estimate from building footprint, low confidence.
How close is Datahouse to the power grid?
The nearest high-voltage substation in OpenStreetMap is Магистральная (220 kV), about 900 m away.
How clean is the power for Datahouse?
The grid in Russia emits about 447 g CO₂ per kWh (2025). Largest sources: gas 45.6%, nuclear 18.3%, coal 17.7%.
Data centers near Presnenskiy
- MSK-IX 3.9 km
- Berzarina Data Center 4.3 km · 5.8 MW
- Linxdatacenter (Moscow) 4.3 km · 2.9 MW
- KIAEHOUSE 4.6 km
- Stack.HTH 5.4 km
- Moscow M10 5.8 km
- Arelion Moscow MSK/O1 5.8 km
- MSU-270 6.2 km
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.