DC BLOX MYR1 - DCBLOX Myrtle Beach
DC BLOX MYR1 - DCBLOX Myrtle Beach is an operational data center operated by DC BLOX Parent in Myrtle Beach, United States. Our footprint estimate of its power is about 23 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | DC BLOX Parent |
| Facility power | 23 MW (range 11 MW to 37 MW) Estimate from building footprint, low confidence. Footprint estimate: about 19,044 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 9,800 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 2 networks PeeringDB. |
| Also known as | DC BLOX Myrtle Beach Cable Landing Station |
| Address | 1401 Howard Avenue |
| Coordinates | 33.67479, -78.94259 |
| Website | dcblox.com/data-centers/myrtle-beach-sc-cable-landing-station |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 115 kV, 1.5 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 230 kV, 9.2 km away |
| HV substations within 10 km | 23 |
| Utility | South Carolina Public Service Authority (state) Electric retail service territory (HIFLD, US government). |
| Balancing authority | SC |
| Nearest gas pipeline | South Carolina PL Corp, interstate pipeline, 2.3 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 275 MW in 6 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 288 g CO₂ per kWh (South Carolina, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 53.9%, gas 21.4%, coal 17.3%, solar 3.8%, hydro 2.1%. Clean power: 61.3% |
| Industrial power price | USD 0.079 per kWh (South Carolina, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 19.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 33.1 °C (2001 to 2025) |
| Cooling degree days | 1,314 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.63 kWh per m² per day |
| Wind at 50 m | 6.5 m/s average |
| Water stress today | Medium - High (20-40%) (South Carolina) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does DC BLOX MYR1 - DCBLOX Myrtle Beach use?
We estimate the facility power at about 23 MW. Estimate from building footprint, low confidence.
How close is DC BLOX MYR1 - DCBLOX Myrtle Beach to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (115 kV), about 1.5 km away. The local utility is South Carolina Public Service Authority, in the SC balancing area.
How clean is the power for DC BLOX MYR1 - DCBLOX Myrtle Beach?
The grid in South Carolina emits about 288 g CO₂ per kWh (2025). Largest sources: nuclear 53.9%, gas 21.4%, coal 17.3%.
Who operates DC BLOX MYR1 - DCBLOX Myrtle Beach?
DC BLOX Parent.
More DC BLOX Parent data centers
- DC BLOX BHM1 - DCBLOX Birmingham United States
- DC BLOX CHA1 - DCBLOX Chattanooga United States
- DC BLOX ATL1 - DCBLOX Atlanta United States
- DC BLOX GSP1 - DCBLOX Greenville United States
- DC BLOX HSV1 - DCBLOX Huntsville United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.