Državni Data Centar DDC
Državni Data Centar DDC is an operational data center operated by Office for Information Technologies and e-Government of Serbia in Kragujevac, Serbia. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Office for Information Technologies and e-Government of Serbia |
| Networks | 4 networks, 1 internet exchanges PeeringDB. |
| Also known as | Data Cloud Technology DC Kragujevac |
| Address | Save Kovačevića 35b |
| Coordinates | 44.01474, 20.92317 |
| Website | ite.gov.rs/tekst/en/35/government-data-centredr-location-in-kragujevac.php |
Power and grid
| Nearest high-voltage substation | КГ005 - Дивље поље, 110 kV, 1.9 km away (Elektromreža Srbije) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Крагујевац 2, 400 kV, 5 km away |
| HV substations within 10 km | 5 |
| Power plants within 50 km | 125 MW in 1 plant
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 693 g CO₂ per kWh (Serbia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 65.1%, hydro 22.1%, gas 6.1%, wind 4.1%, solar 1.3%. Clean power: 28.5% |
| Industrial power price | EUR 0.134 per kWh (Serbia, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 43 °C (2001 to 2025) |
| Cooling degree days | 405 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.67 kWh per m² per day |
| Wind at 50 m | 4.6 m/s average |
| Water stress today | Low - Medium (10-20%) (Serbia) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Državni Data Centar DDC to the power grid?
The nearest high-voltage substation in OpenStreetMap is КГ005 - Дивље поље (110 kV), about 1.9 km away.
How clean is the power for Državni Data Centar DDC?
The grid in Serbia emits about 693 g CO₂ per kWh (2025). Largest sources: coal 65.1%, hydro 22.1%, gas 6.1%.
Who operates Državni Data Centar DDC?
Office for Information Technologies and e-Government of Serbia.
Data centers near Kragujevac
- A1 Data centar 1.6 km · 2.8 MW
- Data center in Kragujevac 1.6 km · 12 MW
- Serbia BroadBand 90.7 km
- Telekom Srbija data centar 94.6 km
- BeotelNet Data Center 94.9 km
- Cetin Data Center 97.9 km
- Absolut Solutions 98.0 km
- PhoenixNAP BELGRADE 98.4 km
Sources
Correct this page or get the data