ITGate PdF (TRN1/TRN2)
ITGate PdF (TRN1/TRN2) is an operational data center operated by IT.Gate in Turin, Italy. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | IT.Gate |
| Networks | 25 networks, 2 internet exchanges PeeringDB. |
| Also known as | Host.it DC1 |
| Address | Corso Svizzera 185, Building 3 |
| Coordinates | 45.09069, 7.66082 |
| Website | itgate.it |
Power and grid
| Nearest high-voltage substation | Martinetto, 220 kV, 900 m away (IRETI) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 34 |
| Power plants within 50 km | 3.3 GW in 20 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 285 g CO₂ per kWh (Italy, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 47.4%, solar 16.8%, hydro 15.7%, wind 8.1%, bioenergy 5.9%. Clean power: 48.7% |
| Industrial power price | EUR 0.173 per kWh (Italy, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 11.2 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 37.8 °C (2001 to 2025) |
| Cooling degree days | 292 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.72 kWh per m² per day |
| Wind at 50 m | 2.9 m/s average |
| Water stress today | High (40-80%) (Italy) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is ITGate PdF (TRN1/TRN2) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Martinetto (220 kV), about 900 m away.
How clean is the power for ITGate PdF (TRN1/TRN2)?
The grid in Italy emits about 285 g CO₂ per kWh (2025). Largest sources: gas 47.4%, solar 16.8%, hydro 15.7%.
Who operates ITGate PdF (TRN1/TRN2)?
IT.Gate.
Data centers near Turin
- Retelit S.p.A. Torino 94 m
- BBBell Torino 153 m
- COLT Datacenter Turin 905 m
- Data center in San Donato 1.0 km
- Data center in Circoiscrizione III 3.7 km · 3.2 MW
- CSI Piemonte 5.9 km
- DC Noovle Cebrosa 8.9 km · 9.2 MW
- Noovle DC Rivoli 9.2 km · 8.1 MW