Noovle DC Rivoli
Noovle DC Rivoli is an operational data center operated by Noovle in Rivoli, Italy. Our footprint estimate of its power is about 8.1 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Noovle |
| Facility power | 8.1 MW (range 4 MW to 13 MW) Estimate from building footprint, low confidence. Footprint estimate: about 6,739 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,500 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Via Carlo Ferrero 10, 10098, Rivoli |
| Opened | 2023 |
| Coordinates | 45.06255, 7.55102 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 132 kV, 300 m away (e-distribuzione S.p.A.) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 220 kV, 3.3 km away |
| HV substations within 10 km | 34 |
| Power plants within 50 km | 2.8 GW in 22 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 285 g CO₂ per kWh (Italy, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 47.4%, solar 16.8%, hydro 15.7%, wind 8.1%, bioenergy 5.9%. Clean power: 48.7% |
| Industrial power price | EUR 0.173 per kWh (Italy, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 11.2 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 37.8 °C (2001 to 2025) |
| Cooling degree days | 292 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.72 kWh per m² per day |
| Wind at 50 m | 2.9 m/s average |
| Water stress today | High (40-80%) (Italy) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Noovle DC Rivoli use?
We estimate the facility power at about 8.1 MW. Estimate from building footprint, low confidence.
How close is Noovle DC Rivoli to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (132 kV), about 300 m away.
How clean is the power for Noovle DC Rivoli?
The grid in Italy emits about 285 g CO₂ per kWh (2025). Largest sources: gas 47.4%, solar 16.8%, hydro 15.7%.
Who operates Noovle DC Rivoli?
Noovle.
Data centers near Rivoli
- Data center in Circoiscrizione III 6.9 km · 3.2 MW
- CSI Piemonte 8.4 km
- Data center in San Donato 8.8 km
- BBBell Torino 9.0 km
- ITGate PdF (TRN1/TRN2) 9.2 km
- Retelit S.p.A. Torino 9.3 km
- COLT Datacenter Turin 9.9 km
- Datacenter TIM-Google 16.7 km · 11 MW