John F. Simms Building
John F. Simms Building is an operational data center operated by SONM in Santa Fe, United States. Our footprint estimate of its power is about 8 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | SONM |
| Facility power | 8 MW (range 4 MW to 13 MW) Estimate from building footprint, low confidence. Footprint estimate: about 3,342 m² building outline x 2 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,400 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Alta Vista Street 715, 87501, Santa Fe |
| Coordinates | 35.67246, -105.95658 |
Power and grid
| Nearest high-voltage substation | Miguel A. Lujan Substation, 115 kV, 3.3 km away (Public Service Company of New Mexico) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Norton Substation, 345 kV, 17.1 km away |
| HV substations within 10 km | 3 |
| Utility | Public Service Co Of Nm (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PNM |
| Nearest gas pipeline | Public Service Co of NM, intrastate pipeline, 4.3 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 18 MW in 6 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 347 g CO₂ per kWh (New Mexico, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 35.7%, gas 26.4%, coal 20.5%, solar 17.4%. Clean power: 53.3% |
| Industrial power price | USD 0.051 per kWh (New Mexico, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 11.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.3 °C (2001 to 2025) |
| Cooling degree days | 489 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.43 kWh per m² per day |
| Wind at 50 m | 5.2 m/s average |
| Water stress today | Extremely High (>80%) (New Mexico) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does John F. Simms Building use?
We estimate the facility power at about 8 MW. Estimate from building footprint, low confidence.
How close is John F. Simms Building to the power grid?
The nearest high-voltage substation in OpenStreetMap is Miguel A. Lujan Substation (115 kV), about 3.3 km away. The local utility is Public Service Co Of Nm, in the PNM balancing area.
How clean is the power for John F. Simms Building?
The grid in New Mexico emits about 347 g CO₂ per kWh (2025). Largest sources: wind 35.7%, gas 26.4%, coal 20.5%.
Who operates John F. Simms Building?
SONM.
Data centers near Santa Fe
- Los Alamos NL Venado 38.9 km · 2.8 MW
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.