KPN data center in Amsterdam-Zuidoost
KPN data center in Amsterdam-Zuidoost is an operational data center operated by KPN in Amsterdam-Zuidoost, Netherlands. Our footprint estimate of its power is about 9 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | KPN |
| Facility power | 9 MW (range 4.5 MW to 14 MW) Estimate from building footprint, low confidence. Footprint estimate: about 2,504 m² building outline x 3 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,800 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Also known as | KPN Amsterdam |
| Opened | 1978 |
| Coordinates | 52.30030, 4.95534 |
Power and grid
| Nearest high-voltage substation | 150 kV Bijlmer Zuid, 150 kV, 800 m away (TenneT) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | 380 kV Diemen, 380 kV, 5.7 km away |
| HV substations within 10 km | 17 |
| Power plants within 50 km | 4.2 GW in 60 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 254 g CO₂ per kWh (Netherlands, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 34.9%, wind 25%, solar 21.1%, coal 7.1%, bioenergy 5.1%. Clean power: 54.2% |
| Industrial power price | EUR 0.139 per kWh (Netherlands, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 32.1 °C (2001 to 2025) |
| Cooling degree days | 53 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.97 kWh per m² per day |
| Wind at 50 m | 7.5 m/s average |
| Water stress today | Low - Medium (10-20%) (Netherlands) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does KPN data center in Amsterdam-Zuidoost use?
We estimate the facility power at about 9 MW. Estimate from building footprint, low confidence.
How close is KPN data center in Amsterdam-Zuidoost to the power grid?
The nearest high-voltage substation in OpenStreetMap is 150 kV Bijlmer Zuid (150 kV), about 800 m away.
How clean is the power for KPN data center in Amsterdam-Zuidoost?
The grid in Netherlands emits about 254 g CO₂ per kWh (2025). Largest sources: gas 34.9%, wind 25%, solar 21.1%.
Who operates KPN data center in Amsterdam-Zuidoost?
KPN.
Data centers near Amsterdam-Zuidoost
- NorthC Amsterdam 2 629 m
- CITIC Telecom CPC Netherlands B.V. 708 m
- Equinix AM1/AM2 - Amsterdam, Luttenbergweg 832 m · 11 MW
- Equinix AM5 - Amsterdam, Schepenbergweg 1.0 km
- 3W-DC01 1.2 km · 3.2 MW
- Equinix AM7 - Amsterdam, Kuiperberweg 1.2 km · 5.9 MW
- Verizon data center in Amsterdam-Zuidoost 1.4 km · 11 MW
- Datacenter.com AMS1 1.7 km