Equinix AM7 - Amsterdam, Kuiperberweg

Equinix AM7 - Amsterdam, Kuiperberweg is an operational data center operated by Equinix in Amsterdam, Netherlands. Our footprint estimate of its power is about 5.9 MW.

Key facts

StatusOperational
OperatorEquinix
Facility power5.9 MW (range 3 MW to 9.4 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 4,919 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 2,500 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks220 networks, 12 internet exchanges
PeeringDB.
Also known asEquinix AM11 - Amsterdam, Lemelerbergweg · Equinix AM7
AddressKuiperbergweg 13
Opened2009
Coordinates52.30308, 4.93801
Websiteequinix.com/locations/netherlands-colocation/amsterdam-data-centers/am7

Power and grid

Nearest high-voltage substation150 kV Bijlmer Zuid, 150 kV, 1.1 km away (TenneT)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substation380 kV Diemen, 380 kV, 6.4 km away
HV substations within 10 km18
Power plants within 50 km4.2 GW in 61 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity254 g CO₂ per kWh (Netherlands, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 34.9%, wind 25%, solar 21.1%, coal 7.1%, bioenergy 5.1%. Clean power: 54.2%
Industrial power priceEUR 0.139 per kWh (Netherlands, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature10.5 °C
NASA POWER, average of 2001 to 2025.
Highest temperature32.1 °C (2001 to 2025)
Cooling degree days53 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.97 kWh per m² per day
Wind at 50 m7.5 m/s average
Water stress todayLow - Medium (10-20%) (Netherlands)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Equinix AM7 - Amsterdam, Kuiperberweg use?

We estimate the facility power at about 5.9 MW. Estimate from building footprint, low confidence.

How close is Equinix AM7 - Amsterdam, Kuiperberweg to the power grid?

The nearest high-voltage substation in OpenStreetMap is 150 kV Bijlmer Zuid (150 kV), about 1.1 km away.

How clean is the power for Equinix AM7 - Amsterdam, Kuiperberweg?

The grid in Netherlands emits about 254 g CO₂ per kWh (2025). Largest sources: gas 34.9%, wind 25%, solar 21.1%.

Who operates Equinix AM7 - Amsterdam, Kuiperberweg?

Equinix.