Equinix PH1 - Philadelphia
Equinix PH1 - Philadelphia is an operational data center operated by Equinix in Philadelphia, United States. Our footprint estimate of its power is about 85 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Facility power | 85 MW (range 42 MW to 136 MW) Estimate from building footprint, low confidence. Footprint estimate: about 11,800 m² building outline x 6 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 36,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 53 networks, 3 internet exchanges PeeringDB. |
| Also known as | DataBank Philadelphia (PHL1) · Netrality Philadelphia - 401 N Broad · Crown Castle Philadelphia (401 N Broad) · Sungard AS Philadelphia · Lumen Philadelphia · Terminal Commerce Building |
| Address | 401 North Broad Street |
| Coordinates | 39.95967, -75.16138 |
| Website | equinix.com |
Power and grid
| Nearest high-voltage substation | Callowhill Substation, 138 kV, 300 m away (PECO) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Grays Ferry Substation, 230 kV, 3.1 km away |
| HV substations within 10 km | 33 |
| Utility | Peco Energy Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM |
| Nearest gas pipeline | Texas Eastern Trans Co, interstate pipeline, 2.9 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 11 GW in 100 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 387 g CO₂ per kWh (Pennsylvania, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 58%, nuclear 30.3%, coal 7.1%, wind 1.4%, solar 1.4%. Clean power: 34.3% |
| Industrial power price | USD 0.105 per kWh (Pennsylvania, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 12.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.1 °C (2001 to 2025) |
| Cooling degree days | 605 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.92 kWh per m² per day |
| Wind at 50 m | 5.5 m/s average |
| Water stress today | Low - Medium (10-20%) (Pennsylvania) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Equinix PH1 - Philadelphia use?
We estimate the facility power at about 85 MW. Estimate from building footprint, low confidence.
How close is Equinix PH1 - Philadelphia to the power grid?
The nearest high-voltage substation in OpenStreetMap is Callowhill Substation (138 kV), about 300 m away. The local utility is Peco Energy Co, in the PJM balancing area.
How clean is the power for Equinix PH1 - Philadelphia?
The grid in Pennsylvania emits about 387 g CO₂ per kWh (2025). Largest sources: gas 58%, nuclear 30.3%, coal 7.1%.
Who operates Equinix PH1 - Philadelphia?
Equinix.
Data centers near Philadelphia
- Crown Castle Philadelphia (1309 Noble) 134 m
- H5 Data Centers Philadelphia (PA01) 360 m
- 833 Chestnut Street 1.2 km
- Quonix Datacenter (2401 Locust St) 1.9 km
- 365 Data Centers Philadelphia (PH2) 3.0 km
- TierPoint Philadelphia 7.5 km
- Data center in Woodbury 14.6 km · 8.2 MW
- DāStor: 3400 Horizon Drive 20.8 km
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
- Equinix MI1 - Miami, NOTA United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.