Data Center Directory

Equinix PH1 - Philadelphia

Equinix PH1 - Philadelphia is an operational data center operated by Equinix in Philadelphia, United States. Our footprint estimate of its power is about 85 MW.

Key facts

StatusOperational
OperatorEquinix
Facility power85 MW (range 42 MW to 136 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 11,800 m² building outline x 6 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 36,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks53 networks, 3 internet exchanges
PeeringDB.
Also known asDataBank Philadelphia (PHL1) · Netrality Philadelphia - 401 N Broad · Crown Castle Philadelphia (401 N Broad) · Sungard AS Philadelphia · Lumen Philadelphia · Terminal Commerce Building
Address401 North Broad Street
Coordinates39.95967, -75.16138
Websiteequinix.com

Power and grid

Nearest high-voltage substationCallowhill Substation, 138 kV, 300 m away (PECO)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationGrays Ferry Substation, 230 kV, 3.1 km away
HV substations within 10 km33
UtilityPeco Energy Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM
Nearest gas pipelineTexas Eastern Trans Co, interstate pipeline, 2.9 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km11 GW in 100 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity387 g CO₂ per kWh (Pennsylvania, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 58%, nuclear 30.3%, coal 7.1%, wind 1.4%, solar 1.4%. Clean power: 34.3%
Industrial power priceUSD 0.105 per kWh (Pennsylvania, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature12.1 °C
NASA POWER, average of 2001 to 2025.
Highest temperature39.1 °C (2001 to 2025)
Cooling degree days605 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.92 kWh per m² per day
Wind at 50 m5.5 m/s average
Water stress todayLow - Medium (10-20%) (Pennsylvania)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Equinix PH1 - Philadelphia use?

We estimate the facility power at about 85 MW. Estimate from building footprint, low confidence.

How close is Equinix PH1 - Philadelphia to the power grid?

The nearest high-voltage substation in OpenStreetMap is Callowhill Substation (138 kV), about 300 m away. The local utility is Peco Energy Co, in the PJM balancing area.

How clean is the power for Equinix PH1 - Philadelphia?

The grid in Pennsylvania emits about 387 g CO₂ per kWh (2025). Largest sources: gas 58%, nuclear 30.3%, coal 7.1%.

Who operates Equinix PH1 - Philadelphia?

Equinix.

Data centers near Philadelphia

More Equinix data centers

Sources

Correct this page or get the data