365 Data Centers Philadelphia (PH2)
365 Data Centers Philadelphia (PH2) is an operational data center operated by 365 Data Centers in Philadelphia, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | 365 Data Centers |
| Networks | 6 networks PeeringDB. |
| Address | 3701 Market St |
| Coordinates | 39.95661, -75.19651 |
| Website | 365datacenters.com/philadelphia-data-center |
Power and grid
| Nearest high-voltage substation | Arsenal Substation, 138 kV, 1.3 km away (Amtrak) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Penn Substation, 230 kV, 1.3 km away |
| HV substations within 10 km | 27 |
| Utility | Peco Energy Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM |
| Nearest gas pipeline | Texas Eastern Trans Co, interstate pipeline, 1.3 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 11 GW in 95 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 387 g CO₂ per kWh (Pennsylvania, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 58%, nuclear 30.3%, coal 7.1%, wind 1.4%, solar 1.4%. Clean power: 34.3% |
| Industrial power price | USD 0.105 per kWh (Pennsylvania, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 12.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.1 °C (2001 to 2025) |
| Cooling degree days | 605 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.92 kWh per m² per day |
| Wind at 50 m | 5.5 m/s average |
| Water stress today | Low - Medium (10-20%) (Pennsylvania) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is 365 Data Centers Philadelphia (PH2) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Arsenal Substation (138 kV), about 1.3 km away. The local utility is Peco Energy Co, in the PJM balancing area.
How clean is the power for 365 Data Centers Philadelphia (PH2)?
The grid in Pennsylvania emits about 387 g CO₂ per kWh (2025). Largest sources: gas 58%, nuclear 30.3%, coal 7.1%.
Who operates 365 Data Centers Philadelphia (PH2)?
365 Data Centers.
Data centers near Philadelphia
- Quonix Datacenter (2401 Locust St) 1.6 km
- H5 Data Centers Philadelphia (PA01) 2.9 km
- Equinix PH1 - Philadelphia 3.0 km · 85 MW
- Crown Castle Philadelphia (1309 Noble) 3.1 km
- 833 Chestnut Street 3.6 km
- TierPoint Philadelphia 7.6 km
- Data center in Woodbury 14.0 km · 8.2 MW
- DāStor: 3400 Horizon Drive 19.0 km
More 365 Data Centers data centers
- 365 Data Centers Bridgewater (BW1) United States
- 365 Data Centers Alpharetta (GA1) United States
- 365 Data Centers Aurora (CO1) United States
- 365 Data Centers Carlstadt (NJ3) United States
- 365 Data Centers Chicago (CH6) United States
- 365 Data Centers Commack (CNY) United States
- 365 Data Centers Detroit (DT1) United States
- 365 Data Centers Ft. Lauderdale (FLL) United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.