Lincoln Rackhouse Silver Spring

Lincoln Rackhouse Silver Spring is an operational data center operated by Lincoln Rackhouse in Silver Spring, United States. Our footprint estimate of its power is about 23 MW.

Key facts

StatusOperational
OperatorLincoln Rackhouse
Facility power23 MW (range 11 MW to 37 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 19,032 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 9,800 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks12 networks, 2 internet exchanges
PeeringDB.
Also known asAgile Silver Spring · Databridge Sites Silver Spring · Lincoln Rackhouse Maryland
Address12401 Prosperity Drive
Coordinates39.05829, -76.96455
Websiterackhouse.com/portfolio/secure-data-center

Power and grid

Nearest high-voltage substationUnnamed substation, 230 kV, 5.9 km away (Potomac Electric Power Company)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km3
UtilityPotomac Electric Power Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM
Nearest gas pipelineTranscontinental Gas PL, interstate pipeline, 13.8 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km4.2 GW in 71 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity124 g CO₂ per kWh (District of Columbia, 2025)
Average of all power made in the area. Ember.
Grid power mixsolar 69.4%, gas 12.2%, bioenergy 9.1%, other renewables 9.1%. Clean power: 87.9%
Industrial power priceUSD 0.185 per kWh (District of Columbia, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature13.2 °C
NASA POWER, average of 2001 to 2025.
Highest temperature40.2 °C (2001 to 2025)
Cooling degree days748 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.04 kWh per m² per day
Wind at 50 m5.9 m/s average
Water stress todayLow (<10%) (District of Columbia)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Lincoln Rackhouse Silver Spring use?

We estimate the facility power at about 23 MW. Estimate from building footprint, low confidence.

How close is Lincoln Rackhouse Silver Spring to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (230 kV), about 5.9 km away. The local utility is Potomac Electric Power Co, in the PJM balancing area.

How clean is the power for Lincoln Rackhouse Silver Spring?

The grid in District of Columbia emits about 124 g CO₂ per kWh (2025). Largest sources: solar 69.4%, gas 12.2%, bioenergy 9.1%.

Who operates Lincoln Rackhouse Silver Spring?

Lincoln Rackhouse.