Lincoln Rackhouse Kansas City
Lincoln Rackhouse Kansas City is an operational data center operated by Lincoln Rackhouse in Kansas City, United States. Our footprint estimate of its power is about 27 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Lincoln Rackhouse |
| Facility power | 27 MW (range 14 MW to 44 MW) Estimate from building footprint, low confidence. Footprint estimate: about 22,758 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 12,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | 11155 N Airworld Dr |
| Coordinates | 39.29560, -94.67394 |
| Website | 11155airworld.com |
Power and grid
| Nearest high-voltage substation | North Congress Substation, 161 kV, 900 m away (Evergy) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Nashua Substation, 345 kV, 8.9 km away |
| HV substations within 10 km | 11 |
| Utility | Platte-Clay Electric Coop, INC (cooperative) Electric retail service territory (HIFLD, US government). |
| Balancing authority | AECI |
| Nearest gas pipeline | Southern Star Central Gas PL Co, interstate pipeline, 11.7 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 4.1 GW in 16 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 674 g CO₂ per kWh (Missouri, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 63.1%, gas 13%, nuclear 9.8%, wind 8.9%, solar 3.3%. Clean power: 23.7% |
| Industrial power price | USD 0.099 per kWh (Missouri, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 12 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 43.3 °C (2001 to 2025) |
| Cooling degree days | 736 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.23 kWh per m² per day |
| Wind at 50 m | 6.8 m/s average |
| Water stress today | Low - Medium (10-20%) (Missouri) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Lincoln Rackhouse Kansas City use?
We estimate the facility power at about 27 MW. Estimate from building footprint, low confidence.
How close is Lincoln Rackhouse Kansas City to the power grid?
The nearest high-voltage substation in OpenStreetMap is North Congress Substation (161 kV), about 900 m away. The local utility is Platte-Clay Electric Coop, INC, in the AECI balancing area.
How clean is the power for Lincoln Rackhouse Kansas City?
The grid in Missouri emits about 674 g CO₂ per kWh (2025). Largest sources: coal 63.1%, gas 13%, nuclear 9.8%.
Who operates Lincoln Rackhouse Kansas City?
Lincoln Rackhouse.
Data centers near Kansas City
- Black Rock Financial Management 351 m · 7.4 MW
- Data center in Parkville 578 m · 9.2 MW
- Data center in Kansas City 1.1 km · 3 MW
- Data center in Parkville 1.2 km · 8.6 MW
- Meta Kansas City Data Center 7.3 km · 139 MW
- Data center in Smithville 7.8 km · 15 MW
- Data center in Smithville 8.6 km · 26 MW
- Data center in Smithville 8.8 km · 26 MW
More Lincoln Rackhouse data centers
- Lincoln Rackhouse Silver Spring United States
- Lincoln Rackhouse Aurora United States
- Lincoln Rackhouse Atlanta United States
- Lincoln Rackhouse Dallas United States
- Lincoln Rackhouse London United Kingdom
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.