Meta Kansas City Data Center

Meta Kansas City Data Center is an operational data center operated by Meta in Smithville, United States. Our footprint estimate of its power is about 139 MW. Likely chips: NVIDIA GPUs (some Meta MTIA) (guess).

Key facts

StatusOperational
OperatorMeta
Facility power139 MW (range 56 MW to 347 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 1,157,936 m² site outline x 0.12 kW per m² of land.
AI chipsNVIDIA GPUs (some Meta MTIA)
Guess from the operator, not confirmed. Meta trains on NVIDIA GPUs and adds in-house MTIA chips for inference.
GPU capacity if all AIabout 59,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Also known asMeta Data Center
Coordinates39.32205, -94.59610

Power and grid

Nearest high-voltage substationFirst Creek, 161 kV, 500 m away (Evergy)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationNashua Substation, 345 kV, 1.6 km away
HV substations within 10 km11
UtilityPlatte-Clay Electric Coop, INC (cooperative)
Electric retail service territory (HIFLD, US government).
Balancing authorityAECI
Nearest gas pipelineSouthern Star Central Gas PL Co, interstate pipeline, 15.5 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km4.1 GW in 16 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity674 g CO₂ per kWh (Missouri, 2025)
Average of all power made in the area. Ember.
Grid power mixcoal 63.1%, gas 13%, nuclear 9.8%, wind 8.9%, solar 3.3%. Clean power: 23.7%
Industrial power priceUSD 0.099 per kWh (Missouri, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature12 °C
NASA POWER, average of 2001 to 2025.
Highest temperature43.3 °C (2001 to 2025)
Cooling degree days736 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.23 kWh per m² per day
Wind at 50 m6.8 m/s average
Water stress todayLow - Medium (10-20%) (Missouri)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Meta Kansas City Data Center use?

We estimate the facility power at about 139 MW. Estimate from building footprint, low confidence.

What chips does Meta Kansas City Data Center use?

No chips are reported. Based on the operator, the likely chips are NVIDIA GPUs (some Meta MTIA).

How close is Meta Kansas City Data Center to the power grid?

The nearest high-voltage substation in OpenStreetMap is First Creek (161 kV), about 500 m away. The local utility is Platte-Clay Electric Coop, INC, in the AECI balancing area.

How clean is the power for Meta Kansas City Data Center?

The grid in Missouri emits about 674 g CO₂ per kWh (2025). Largest sources: coal 63.1%, gas 13%, nuclear 9.8%.

Who operates Meta Kansas City Data Center?

Meta.