Data Center Directory

LuxConnect DC1.1 - Bettembourg

LuxConnect DC1.1 - Bettembourg is a data center under construction operated by LuxConnect in Bettembourg, Luxembourg. Our footprint estimate of its power is about 13 MW.

Key facts

StatusUnder construction
OperatorLuxConnect
Facility power13 MW (range 6.6 MW to 21 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 10,955 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 5,600 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks50 networks, 3 internet exchanges
PeeringDB.
Also known asSecureIT DCB1.1 · SecureIT DCB1.2 · LuxConnect DC1.2 - Bettembourg · LuxConnect DC1.3 - Bettembourg · ICT Campus Bettembourg DC 1.3 · ICT Campus Bettembourg DC 1.2
Address202, Z.a.e. Wolser F, L-3290 Bettembourg
Coordinates49.50492, 6.11352
Websiteluxconnect.lu

Power and grid

Nearest high-voltage substationBerchem, 220 kV, 5.4 km away (CREOS; SNCFL)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km2
Power plants within 50 km6.9 GW in 34 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity111 g CO₂ per kWh (Luxembourg, 2025)
Average of all power made in the area. Ember.
Grid power mixsolar 37.4%, wind 27.1%, bioenergy 23.4%, hydro 4.4%, oil and other fossil 4%. Clean power: 92.3%
Industrial power priceEUR 0.104 per kWh (Luxembourg, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature9.6 °C
NASA POWER, average of 2001 to 2025.
Highest temperature39.7 °C (2001 to 2025)
Cooling degree days137 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.15 kWh per m² per day
Wind at 50 m6 m/s average
Water stress todayMedium - High (20-40%) (Luxembourg)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050High (40-80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does LuxConnect DC1.1 - Bettembourg use?

We estimate the facility power at about 13 MW. Estimate from building footprint, low confidence.

How close is LuxConnect DC1.1 - Bettembourg to the power grid?

The nearest high-voltage substation in OpenStreetMap is Berchem (220 kV), about 5.4 km away.

How clean is the power for LuxConnect DC1.1 - Bettembourg?

The grid in Luxembourg emits about 111 g CO₂ per kWh (2025). Largest sources: solar 37.4%, wind 27.1%, bioenergy 23.4%.

Who operates LuxConnect DC1.1 - Bettembourg?

LuxConnect.