Data Center Directory

DATA4 Luxembourg - LUX

DATA4 Luxembourg - LUX is an operational data center operated by DATA4 s.a r.l in Bettembourg, Luxembourg. Our footprint estimate of its power is about 7.6 MW.

Key facts

StatusOperational
OperatorDATA4 s.a r.l
Facility power7.6 MW (range 3.8 MW to 12 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 6,337 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 3,200 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks2 networks
PeeringDB.
Also known asICT Campus Bettembourg DC 1.1
Address4 Rue Graham Bell
Coordinates49.50481, 6.11237
Websitedata4group.com

Power and grid

Nearest high-voltage substationBerchem, 220 kV, 5.5 km away (CREOS; SNCFL)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km2
Power plants within 50 km6.9 GW in 34 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity111 g CO₂ per kWh (Luxembourg, 2025)
Average of all power made in the area. Ember.
Grid power mixsolar 37.4%, wind 27.1%, bioenergy 23.4%, hydro 4.4%, oil and other fossil 4%. Clean power: 92.3%
Industrial power priceEUR 0.104 per kWh (Luxembourg, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature9.6 °C
NASA POWER, average of 2001 to 2025.
Highest temperature39.7 °C (2001 to 2025)
Cooling degree days137 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.15 kWh per m² per day
Wind at 50 m6 m/s average
Water stress todayMedium - High (20-40%) (Luxembourg)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050High (40-80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does DATA4 Luxembourg - LUX use?

We estimate the facility power at about 7.6 MW. Estimate from building footprint, low confidence.

How close is DATA4 Luxembourg - LUX to the power grid?

The nearest high-voltage substation in OpenStreetMap is Berchem (220 kV), about 5.5 km away.

How clean is the power for DATA4 Luxembourg - LUX?

The grid in Luxembourg emits about 111 g CO₂ per kWh (2025). Largest sources: solar 37.4%, wind 27.1%, bioenergy 23.4%.

Who operates DATA4 Luxembourg - LUX?

DATA4 s.a r.l.

Data centers near Bettembourg

More DATA4 s.a r.l data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.