Data 4 Warszawy
Data 4 Warszawy is an operational data center operated by DATA4 s.a r.l in Jawczyce,, Poland. Our footprint estimate of its power is about 1.4 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | DATA4 s.a r.l |
| Facility power | 1.4 MW (range 0.6 MW to 3.5 MW) Estimate from building footprint, low confidence. Footprint estimate: about 11,696 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 600 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 2 networks PeeringDB. |
| Also known as | Data4 Pologne WAW1 |
| Address | Przyparkowa 21 - 05-850 Jawczyce |
| Coordinates | 52.21150, 20.85063 |
| Website | data4group.com/pl/data-centers-warsaw-poland |
Power and grid
| Nearest high-voltage substation | Podstacja trakcyjna „Gołąbki”, 110 kV, 600 m away (PGE Energetyka Kolejowa) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Stacja elektroenergetyczna 220/110 kV „SE Mory”, 220 kV, 1.9 km away |
| HV substations within 10 km | 26 |
| Power plants within 50 km | 1.4 GW in 5 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 591 g CO₂ per kWh (Poland, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 50.6%, gas 14.4%, wind 13.9%, solar 11.3%, bioenergy 4.9%. Clean power: 31.2% |
| Industrial power price | EUR 0.169 per kWh (Poland, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 8.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 36.9 °C (2001 to 2025) |
| Cooling degree days | 200 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.98 kWh per m² per day |
| Wind at 50 m | 6.3 m/s average |
| Water stress today | Low - Medium (10-20%) (Poland) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Data 4 Warszawy use?
We estimate the facility power at about 1.4 MW. Estimate from building footprint, low confidence.
How close is Data 4 Warszawy to the power grid?
The nearest high-voltage substation in OpenStreetMap is Podstacja trakcyjna „Gołąbki” (110 kV), about 600 m away.
How clean is the power for Data 4 Warszawy?
The grid in Poland emits about 591 g CO₂ per kWh (2025). Largest sources: coal 50.6%, gas 14.4%, wind 13.9%.
Who operates Data 4 Warszawy?
DATA4 s.a r.l.
Data centers near Jawczyce,
- Data4 Pologne WAW2 80 m · 1.1 MW
- Netia Data Center MIND 148 m · 0.7 MW
- EdgeConneX Warsaw (EDCWAW03) 2.5 km
- OVHcloud Ożarów (WAW-1) 2.9 km · 8.9 MW
- ATMAN Data Center Warsaw-3 (WAW-3, Ożarowska 66B) 3.1 km · 7.8 MW
- Equinix WA3 - Warsaw 5.3 km · 1.7 MW
- Datahouse Warsaw 5.4 km
- EdgeConneX Warsaw (EDCWAW02) 6.5 km
More DATA4 s.a r.l data centers
- DATA4 Luxembourg - LUX Luxembourg
- DATA4 Madrid-Alcobendas - MAD1 Spain
- DATA4 Milan-Cornaredo - MIL1 Italy
- DATA4 Paris Marcoussis PAR2 France