NorthC Biel (Bern)
NorthC Biel (Bern) is an operational data center operated by NorthC Schweiz in Biel/Bienne, Switzerland. Our footprint estimate of its power is about 0.6 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | NorthC Schweiz |
| Facility power | 0.6 MW (range 0.2 MW to 1.4 MW) Estimate from building footprint, low confidence. Footprint estimate: about 4,764 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 260 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 3 networks PeeringDB. |
| Also known as | NorthC Biel data center · Datacube Biel |
| Address | Tennisweg 6 |
| Coordinates | 47.15570, 7.27917 |
| Website | northcdatacenters.com/ch-de |
Power and grid
| Nearest high-voltage substation | Unterwerk Pieterlen, 132 kV, 5.8 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Poste électrique de Bassecourt, 380 kV, 20.3 km away |
| HV substations within 10 km | 2 |
| Power plants within 50 km | 505 MW in 38 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 39 g CO₂ per kWh (Switzerland, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 52.3%, nuclear 29.9%, solar 12.1%, oil and other fossil 1.9%, bioenergy 1.6%. Clean power: 97.7% |
Climate and water
| Average temperature | 8.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 34.1 °C (2001 to 2025) |
| Cooling degree days | 95 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.43 kWh per m² per day |
| Wind at 50 m | 3.9 m/s average |
| Water stress today | Low (<10%) (Bern) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does NorthC Biel (Bern) use?
We estimate the facility power at about 0.6 MW. Estimate from building footprint, low confidence.
How close is NorthC Biel (Bern) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Unterwerk Pieterlen (132 kV), about 5.8 km away.
How clean is the power for NorthC Biel (Bern)?
The grid in Switzerland emits about 39 g CO₂ per kWh (2025). Largest sources: hydro 52.3%, nuclear 29.9%, solar 12.1%.
Who operates NorthC Biel (Bern)?
NorthC Schweiz.
Data centers near Biel/Bienne
- ColoBâle 3.3 km
- LAN Services AG - Communication Center cc.ch 4.0 km
- data11 19.6 km
- VTLWaveNet Bern 25.1 km
- colobern.ch Bern 26.0 km
- senseLAN B20 33.9 km
- senseLAN D01 35.2 km
- High DC 37.0 km
More NorthC Schweiz data centers
- NorthC Münchenstein (Basel) 1 Switzerland
- NorthC Münchenstein (Basel) 2 Switzerland
- NorthC Winterthur (Zürich) Switzerland
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.