Psychz Networks LAX1
Psychz Networks LAX1 is an operational data center operated by Psychz Networks in Los Angeles, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Psychz Networks |
| Networks | 8 networks PeeringDB. |
| Address | 700 Wilshire Blvd #200 |
| Coordinates | 34.04868, -118.25753 |
| Website | psychz.net |
Power and grid
| Nearest high-voltage substation | River Switching Station, 230 kV, 2.8 km away (Los Angeles Department of Water and Power) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 5 |
| Utility | Los Angeles Department Of Water & Power (municipal) Electric retail service territory (HIFLD, US government). |
| Balancing authority | LDWP |
| Nearest gas pipeline | Southern California Gas Co, intrastate pipeline, 7 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 11 GW in 91 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 189 g CO₂ per kWh (California, 2025) Average of all power made in the area. Ember. |
| Grid power mix | solar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7% |
| Industrial power price | USD 0.241 per kWh (California, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 17.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.5 °C (2001 to 2025) |
| Cooling degree days | 530 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.65 kWh per m² per day |
| Wind at 50 m | 4 m/s average |
| Water stress today | Extremely High (>80%) (California) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Psychz Networks LAX1 to the power grid?
The nearest high-voltage substation in OpenStreetMap is River Switching Station (230 kV), about 2.8 km away. The local utility is Los Angeles Department Of Water & Power, in the LDWP balancing area.
How clean is the power for Psychz Networks LAX1?
The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.
Who operates Psychz Networks LAX1?
Psychz Networks.
Data centers near Los Angeles
- Telehouse - Los Angeles 68 m
- MultaCom Main 77 m
- Equinix LA1 - Los Angeles 133 m · 70 MW
- LADC5 - 650 S Grand Ave 187 m
- Equinix LA2 - Los Angeles 191 m
- CoreSite - Los Angeles (LA1) One Wilshire 199 m · 45 MW
- JMA NAC Los Angeles 218 m
- 800 south hope 328 m