LADC5 - 650 S Grand Ave
LADC5 - 650 S Grand Ave is an operational data center operated by Colocation America in Los Angeles, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Colocation America |
| Networks | 1 networks PeeringDB. |
| Also known as | Subrigo LAX11 |
| Address | 650 S Grand Ave |
| Coordinates | 34.04742, -118.25618 |
| Website | colocationamerica.com/data-center-locations/los-angeles.htm |
Power and grid
| Nearest high-voltage substation | River Switching Station, 230 kV, 2.7 km away (Los Angeles Department of Water and Power) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 5 |
| Utility | Los Angeles Department Of Water & Power (municipal) Electric retail service territory (HIFLD, US government). |
| Balancing authority | LDWP |
| Nearest gas pipeline | Southern California Gas Co, intrastate pipeline, 7 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 11 GW in 91 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 189 g CO₂ per kWh (California, 2025) Average of all power made in the area. Ember. |
| Grid power mix | solar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7% |
| Industrial power price | USD 0.241 per kWh (California, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 17.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.5 °C (2001 to 2025) |
| Cooling degree days | 530 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.65 kWh per m² per day |
| Wind at 50 m | 4 m/s average |
| Water stress today | Extremely High (>80%) (California) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is LADC5 - 650 S Grand Ave to the power grid?
The nearest high-voltage substation in OpenStreetMap is River Switching Station (230 kV), about 2.7 km away. The local utility is Los Angeles Department Of Water & Power, in the LDWP balancing area.
How clean is the power for LADC5 - 650 S Grand Ave?
The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.
Who operates LADC5 - 650 S Grand Ave?
Colocation America.
Data centers near Los Angeles
- CoreSite - Los Angeles (LA1) One Wilshire 81 m · 45 MW
- Equinix LA1 - Los Angeles 104 m · 70 MW
- Telehouse - Los Angeles 120 m
- JMA NAC Los Angeles 144 m
- Psychz Networks LAX1 187 m
- MultaCom Main 214 m
- 800 south hope 304 m
- Equinix LA2 - Los Angeles 354 m
More Colocation America data centers
- NJDC2 - 300 J F Kennedy Blvd United States
- PDC1 - 9999 Hamilton blvd United States
- PDC2 - 1000 Adams ave United States
- BDC1 - 34 Saint Martin Dr United States
- CDC4 - 1808 Swift Dr United States
- HDC1 - 108 Bank St United States
- PDC3 - 3949 Schelden Cir United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.