PDC1 - 9999 Hamilton blvd
PDC1 - 9999 Hamilton blvd is an operational data center operated by Colocation America in Breinigsville, United States. Our footprint estimate of its power is about 20 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Colocation America |
| Facility power | 20 MW (range 10 MW to 32 MW) Estimate from building footprint, low confidence. Footprint estimate: about 16,726 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 8,500 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 5 networks PeeringDB. |
| Also known as | TierPoint Allentown-TekPark · Allentown-TekPark |
| Address | 9999 Hamilton blvd, unit 4 |
| Coordinates | 40.54424, -75.65572 |
| Website | colocationamerica.com/data-center-locations/philadelphia |
Power and grid
| Nearest high-voltage substation | Breinigsville Substation, 500 kV, 1.4 km away (PPL) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 3 |
| Utility | Ppl Electric Utilities Corp (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM |
| Nearest gas pipeline | Texas Eastern Trans Co, interstate pipeline, 13.2 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 5.6 GW in 26 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 387 g CO₂ per kWh (Pennsylvania, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 58%, nuclear 30.3%, coal 7.1%, wind 1.4%, solar 1.4%. Clean power: 34.3% |
| Industrial power price | USD 0.105 per kWh (Pennsylvania, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 10.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.9 °C (2001 to 2025) |
| Cooling degree days | 508 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.86 kWh per m² per day |
| Wind at 50 m | 4.5 m/s average |
| Water stress today | Low - Medium (10-20%) (Pennsylvania) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does PDC1 - 9999 Hamilton blvd use?
We estimate the facility power at about 20 MW. Estimate from building footprint, low confidence.
How close is PDC1 - 9999 Hamilton blvd to the power grid?
The nearest high-voltage substation in OpenStreetMap is Breinigsville Substation (500 kV), about 1.4 km away. The local utility is Ppl Electric Utilities Corp, in the PJM balancing area.
How clean is the power for PDC1 - 9999 Hamilton blvd?
The grid in Pennsylvania emits about 387 g CO₂ per kWh (2025). Largest sources: gas 58%, nuclear 30.3%, coal 7.1%.
Who operates PDC1 - 9999 Hamilton blvd?
Colocation America.
Data centers near Breinigsville
- Flexential Allentown Data Center 19.6 km · 9.3 MW
- TierPoint Bethlehem 27.5 km
- PDC3 - 3949 Schelden Cir 27.6 km
- Direct LTx Reading 33.0 km
- Omega PA1 37.2 km
- Flexential - Philadelphia/Collegeville (PHL01) 46.1 km · 13 MW
- Lumen Norristown 50.9 km · 6.5 MW
- PDC2 - 1000 Adams ave 51.0 km · 13 MW
More Colocation America data centers
- NJDC2 - 300 J F Kennedy Blvd United States
- PDC2 - 1000 Adams ave United States
- BDC1 - 34 Saint Martin Dr United States
- CDC4 - 1808 Swift Dr United States
- HDC1 - 108 Bank St United States
- LADC5 - 650 S Grand Ave United States
- PDC3 - 3949 Schelden Cir United States