Lumen Norristown
Lumen Norristown is an operational data center operated by Lumen Technologies in Audubon, United States. Our footprint estimate of its power is about 6.5 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Lumen Technologies |
| Facility power | 6.5 MW (range 3.3 MW to 10 MW) Estimate from building footprint, low confidence. Footprint estimate: about 5,425 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,800 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 40.12707, -75.40866 |
Power and grid
| Nearest high-voltage substation | Betzwood Substation, 230 kV, 1.7 km away (PECO) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 8 |
| Utility | Peco Energy Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM |
| Nearest gas pipeline | Transcontinental Gas PL, interstate pipeline, 100 m away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 10 GW in 72 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 387 g CO₂ per kWh (Pennsylvania, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 58%, nuclear 30.3%, coal 7.1%, wind 1.4%, solar 1.4%. Clean power: 34.3% |
| Industrial power price | USD 0.105 per kWh (Pennsylvania, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 11.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.4 °C (2001 to 2025) |
| Cooling degree days | 618 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.86 kWh per m² per day |
| Wind at 50 m | 4.8 m/s average |
| Water stress today | Low - Medium (10-20%) (Pennsylvania) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Lumen Norristown use?
We estimate the facility power at about 6.5 MW. Estimate from building footprint, low confidence.
How close is Lumen Norristown to the power grid?
The nearest high-voltage substation in OpenStreetMap is Betzwood Substation (230 kV), about 1.7 km away. The local utility is Peco Energy Co, in the PJM balancing area.
How clean is the power for Lumen Norristown?
The grid in Pennsylvania emits about 387 g CO₂ per kWh (2025). Largest sources: gas 58%, nuclear 30.3%, coal 7.1%.
Who operates Lumen Norristown?
Lumen Technologies.
Data centers near Audubon
- PDC2 - 1000 Adams ave 1.2 km · 13 MW
- Flexential - Philadelphia/Collegeville (PHL01) 6.6 km · 13 MW
- DāStor: 3400 Horizon Drive 7.3 km
- 365 Data Centers Philadelphia (PH2) 26.2 km
- Quonix Datacenter (2401 Locust St) 27.7 km
- H5 Data Centers Philadelphia (PA01) 27.8 km
- Crown Castle Philadelphia (1309 Noble) 28.1 km
- Equinix PH1 - Philadelphia 28.1 km · 85 MW
More Lumen Technologies data centers
- Level(3) Weehawken United States
- Level(3) Seattle (Denny Way) United States
- Level(3) Denver United States
- Level(3) London (Braham Street) United Kingdom
- Level(3) McLean United States
- Lumen Ashburn United States
- Level(3) Sunnyvale United States
- Level(3) Dallas United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.