Level(3) Weehawken
Level(3) Weehawken is an operational data center operated by Lumen Technologies in Weehawken, United States. Our footprint estimate of its power is about 76 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Lumen Technologies |
| Facility power | 76 MW (range 38 MW to 121 MW) Estimate from building footprint, low confidence. Footprint estimate: about 15,733 m² building outline x 4 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 32,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 10 networks, 1 internet exchanges PeeringDB. |
| Also known as | Digital Realty New Jersey EWR10 (closed) · Centersquare New Jersey (EWR2) · Digital Realty New Jersey EWR10 |
| Address | 300 JFK Boulevard East |
| Coordinates | 40.76183, -74.02503 |
| Website | level3.com |
Power and grid
| Utility | Public Service Elec & Gas Co (investor owned) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | PJM |
| Nearest gas pipeline | Transcontinental Gas PL, interstate pipeline, 4.1 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 265 g CO₂ per kWh (New Jersey, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 45.8%, nuclear 43.2%, solar 9%, oil and other fossil 1.5%, bioenergy 0.9%. Clean power: 52.8% |
| Industrial power price | USD 0.162 per kWh (New Jersey, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 11.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 38.7 °C (2001 to 2025) |
| Cooling degree days | 504 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.87 kWh per m² per day |
| Wind at 50 m | 5.3 m/s average |
| Water stress today | Medium - High (20-40%) (New Jersey) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Level(3) Weehawken use?
We estimate the facility power at about 76 MW. Estimate from building footprint, low confidence.
How clean is the power for Level(3) Weehawken?
The grid in New Jersey emits about 265 g CO₂ per kWh (2025). Largest sources: gas 45.8%, nuclear 43.2%, solar 9%.
Who operates Level(3) Weehawken?
Lumen Technologies.
Data centers near Weehawken
- Cyxtera (Digital Realty Trust) Citibank Data Center 131 m · 43 MW
- Lumen New York 1.9 km
- Level(3) New York 2.5 km
- Digital Realty NYC (111 8th Ave) 2.9 km
- Host Color 3.7 km
- Equinix NY3 - New York, Secaucus 3.9 km · 9.2 MW
- Equinix NY7 - New York, North Bergen 3.9 km · 12 MW
- Newport Financial Center 4.0 km
More Lumen Technologies data centers
- Level(3) Seattle (Denny Way) United States
- Level(3) Denver United States
- Level(3) London (Braham Street) United Kingdom
- Level(3) McLean United States
- Lumen Ashburn United States
- Level(3) Sunnyvale United States
- Level(3) Dallas United States
- Lumen Norristown United States